Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 10, 2026
You can try adjusting the Modulation & Overshoot settings in the MMI to start with. Enter installer mode to adjust these.
My 2 bed mid-terrace definitely dropped consistently after the heat pump was installed. Previously, because I still have single glazing, I used a smal...
Plus the pipe is in contact with the ground so it's a cold/moisture bridge and needs to be lifted or at least an air gap created underneath.
If it's accessible then it should be fine. The cylinder won't get even warm on the outside. Mine is in the loft which was annoying for about 3 weeks...
If it's accessible then it should be fine. The cylinder won't get even warm on the outside. Mine is in the loft which was annoying for about 3 weeks...
I found because I have very low heat loss I can set back the temp by only 1C during the higher rate periods because the Daikin overshoots 1-1.5C regar...
Three things that caused noise in my system after commissioning. Volumiser was gurgling which just turned out to be the air bleed valve not open. ...
@georgea You system isn't too different from mine. I don't have UFH and my house is a 2 bed mid-terrace so maybe a bit smaller. Heat loss 3.3 @ -3C...
Slight correct to the above defrost behaviour as the fan only ramps at the beginning and end of the cycle. The bit in the middle is when both the wate...
ASHP Model: Daikin Altherma 3M 4KW House loss: Calculated 3.3 at -3C, definitely overestimated though. Control mode: Weather Comp + Thermostat wit...
With existing rads it seems easier to just install A2W. I've seen some larger houses with multiple internal A2A units have pipework running all over t...
Valiant & Daikin have a form of load compensation or room influence which can dynamically adjust the WDC by a few degrees based on what thermostat...
- 26 Forums
- 2,623 Topics
- 61.3 K Posts
- 1,005 Online
- 7,004 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Brown Oily Residue Blocking Air Vent and Weeping Relief Valve... Anyone Seen This?
@aventus-eco any words of wisdom here?
By Mars , 24 minutes ago
-
RE: Grant Aerona3 - Home Assistant control via Modbus
I'm trying to control my Grant Areona 3 with modbus, I ...
By Vanq , 31 minutes ago
-
Is Traditional Radiator Balancing Tosh?
So, conventional HP wisdom says to balance the rads by ...
By markspencersmith , 53 minutes ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Manufacturer: appliances direct/superheat Model: 7Kw ...
By Adrian , 1 hour ago
-
RE: Peak Energy Products V therm 16kW unit heat pump not reaching flow temperature
As a final update on this thread from me; Ribble Valley...
By DaveC , 1 hour ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
Fantastic. This is all I needed. Afew planning applic...
By Batpred , 5 hours ago
-
RE: Renewables & Heat Pumps in the News
Commentary on DCs and the grid in the EU. A bit on some...
By Jeff , 9 hours ago
-
RE: Mitsubishi Ecodan not good enough ?
If you put a fan in a pipe you get a much more efficien...
By bobflux , 18 hours ago
-
RE: Mitsubishi ecodan settings
As the owner of a 8kW Ecodan R290 maybe I can help. ...
By RobS , 18 hours ago
-
Wall mounting makes sense. We are now looking for an in...
By Batpred , 22 hours ago
-
RE: Vaillant AroTherm Plus 7kW
Thank you, watson did allow me to find this one! Our ...
By Batpred , 22 hours ago
-
RE: Our 10 year old Grant heat pump failed
Sorry to hear. Grant seem to be selling the R290 pump...
By Batpred , 22 hours ago
-
RE: Jokes and fun posts about heat pumps and renewables
.. apparently with american fuel. 🙃
By Batpred , 22 hours ago
-
RE: The Watchdog That Watched and Waited
Spot on. The watchdog that knows how to never take the ...
By Batpred , 22 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Yes, the cost difference may be marginal, if you are lu...
By Batpred , 23 hours ago
-
RE: Don’t Install a Heat Pump Until You Read This
In our latest update, we attempt to show what a poor he...
By Mars , 23 hours ago
-
RE: Heat Pump Pipe Sizing Question
No the retrofit strategy is already published. It's on...
By JamesPa , 23 hours ago
-
RE: Ecodan spells out end of R32 for real environmental alternative
I think I saw the answer to this on another thread but ...
By Batpred , 24 hours ago
-
RE: Mitsubishi Ecodan FTC6, Evohome & Economy 7. Getting Two Zones to Work Together
This is what we are trying to avoid if we go Ecodan, mu...
By Batpred , 1 day ago
-
Great points, I agree it is overused. It is also a grea...
By Batpred , 1 day ago
-
RE: GSHP Kaput After 16 Years: New Compressor or Switch to ASHP? Advice Welcome
On old (non inverter) compressors there’s sometimes a ‘...
By robl , 2 days ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@editor It's available here -
By HarrisonC , 3 days ago
-
@painter26 i am in Lightwater and midea trained. Sounds...
By Wizard , 3 days ago