Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jul 23, 2026
Ooh, heat pumps in neon blue wrap 🤣 🤣 🤣
My Samsung Gen6 (probably same controller as yours) only stores annual data for the current year (2025) so there is no data for last year. Looking at ...
Sufficient system volume is also essential for ensuring there is enough energy in the system to perform effective defrost cycles (unless there is some...
We run a standard flow temp of around 32C all year round (certainly between 30-35C) and achieve a comfortable (for us) 20C room temp. Our radiators ar...
@howardp99 We have an electric Rangemaster cooker that uses propane for the hobs. We pay around £95 for a 47kg cylinder which lasts us around 18-24 mo...
@howardp99 Yes, I get how the inverter rating is limiting, especially during the evening peak in winter when cooking. I figure our ASHP and background...
You would think, but when I had my Powerwall 3 installed, the main installer/electrician was here for 3 full days doing the battery and gateway instal...
@diverted-energy I totally agree, but a regulated minimum would at least be a starting point and if it achieved nothing other than reducing export of ...
I remember reading about that at the time. So long as energy is just a commodity that can be traded to the highest bidder... I don't have the answ...
I agree @tim441. I would love to see planning regulations for all new developments of any size (say, more than 5 properties) be required to fit 3-4kWp...
GivEnergy, Enphase, SolarEdge and Tesla batteries are now supported. It's a net metering tariff where import and export cost the same. Octopus control...
- 26 Forums
- 2,722 Topics
- 63.7 K Posts
- 868 Online
- 7,124 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Advice on my Heat Pump Journey: Old Stone Built Detached Cottage
@paulc my view after reading the whole thread is that I...
By Mars , 19 minutes ago
-
RE: Missing flow temperature in Heat Geek proposal
@jamespa Thanks, will do.
By sttpd1917 , 13 hours ago
-
Heat of vaporization of water is 2.25 MJ/kg (0.625 kWh/...
By bobflux , 13 hours ago
-
RE: Air to air bus grant installer anywhere
society and politics require things to be made more com...
By Batpred , 1 day ago
-
RE: Existing Solar Panel installation - structural roof calculation check
What will also happen is that they see that there is so...
By EtchedPixels , 2 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
@indevolt-tech can you please assist @blizzardgreen.
By Mars , 2 days ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
It's a great looking piece of kit and the 5kw is very q...
By avenir , 3 days ago
-
RE: Vaillant Arotherm Pro vs new Plus
So with the dedicated Hager CU, flipping the big red bu...
By Batpred , 4 days ago
-
Well I usually do it by feel, which is a slight problem...
By Transparent , 5 days ago
-
@jeff I am well aware of the riskiness of such investme...
By Toodles , 5 days ago
-
Fully understood and entirely reasonable! On the home ...
By JamesPa , 5 days ago
-
RE: Electricity price predictions
So I am really having difficulty trying to work out wha...
By bontwoody , 5 days ago
-
Ok Well almost certainly it could be used instead of ...
By JamesPa , 6 days ago
-
RE: Samsung heat pump - data cable issue
Samsung reference it as "RS485 - COMM" in my manual. ...
By Old_Scientist , 6 days ago