Reply
RE: Electricity use for heat pumps - comparing homes and consumption

Hi @skd just thought I'd add that a conversation with @toodles drifted in this direction also - some data for two Daikin-powered homes here. Not in th...

2 years ago
Reply
RE: Daikin Altherma 3 8kW not working as needed

Hi @toodles sounds very much like our situation with our Daikin - we have three people in the house, two of us working from home. Our daily 'backgroun...

2 years ago
Reply
RE: Daikin Altherma 3 8kW not working as needed

Hi @toodles thanks for the update. My 16kw Daikin HT (run at LT) uses one of the old controllers - the next to useless EKRUAHTB - which gives me no in...

2 years ago
Reply
RE: Daikin Altherma 3 8kW not working as needed

@toodles I read this with interest - I have a Daikin too and have been fiddling with the WCC forever. I like this approach (if I'm right in my interpr...

2 years ago
Reply
RE: Rethinking Export Tariffs: A Step Towards Fair Compensation for Domestic Solar Energy Producers

I'm in Italy and we are paid the monthly average wholesale rate (publicly available from www.mercatoelettrico.org) for solar sent to the grid. My paym...

2 years ago
Reply
RE: Heat pump efficiency v Outside Air Temperature

@bontwoody great minds etc... 🙂 Interesting way to cut the data - I think I'll run my numbers in a similar way - I don't have any COP data unfortuna...

2 years ago
Reply
RE: Heat pump efficiency v Outside Air Temperature

Very interesting @mike-patrick - I've been playing with something similar as our supplier recently started publishing our consumption data (and solar ...

2 years ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

Thanks @jamespa - the flow in the manual is a bit confusing but in Capture 3 Daikin seem to also recommend/ mandate a 'balancing bottle' in the scenar...

2 years ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

Hi all - following this thread with interest if a little over my head at times...I took a look at my Daikin Altherma manuals (2020 install) and the at...

2 years ago
Reply
RE: Secondary pump speed - how much slower should it be?

Hi @toodles I have a Daikin Altherma HT with a LLH feeding two 'zones' - one for UFH and one for rads. I have two DAB secondary/ circulating pumps imm...

2 years ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

Hi @toodles don't know if you've seen them before but there a couple of articles which may be of interest from Protons for Breakfast regarding his sys...

2 years ago
Reply
RE: Air source heat pumps and noise

Just for the tape my OAT in Avigliano Umbro is given (by www.visualcrossing.com/weather/weather-data-services) as 6C at 9am on 28/12, with a 'feels li...

2 years ago