Your logic is sound. I've got similar battery capacity (2 x Powerwalls) which have only hit empty once so far this autumn/winter with my 7kW Vaillant ...
As someone who is considering buying an EV within a few years, I would much prefer to invest in one which supports V2H and V2G given that the vehicle ...
A thought, FWIW. Where is the OAT sensor located and does your system configuration allow you to set an offset? I've noticed that the OAT sensor (loca...
Try reducing the DHW hysteresis setting and schedule the DHW to come on just before and during periods when the hot water is likely to be used. The hy...
Given the very slow response of UFH, I'm surprised that it's noticeable if the heating goes off or an hour or so. And a new build, if insulated to cur...
Is the buffer tank in the house? If so, any heat loss should be contributing to the domestic heating and, for the summer half the heat should be makin...
I've just checked in my Vaillant app and see that I can set my Arotherm to heat the hot water up to 70C which is higher than you are envisaging. The d...
In the Vaillant app go to Settings (the cog wheel icon) > Control > Heating > Weekly planner and put in a temperature below the setback value...
Here's a good example of how to build a hot water cylinder shed starting with a well-insulated base.
I have to wonder about the temperature inside that shed. Earlier you noted that it's a pressed steel shed. Did the installer add a generous layer of i...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 180 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Low Flow Rate Error - 8 kW Ideal Logic ASHP - Help!
@editor we now fit 800 micron Y strainers rather than t...
By ASHP-BOBBA , 39 seconds ago
-
As promised, here's Cap'n Burrows delivering on his pro...
By Mars , 2 minutes ago
-
RE: Heat Pump Installers: Competence, Illusion and the Hard Truth Homeowners Must Face
@Fiona, I really don’t want to disappoint you, but I ha...
By Mars , 15 minutes ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
@dgclimatecontrol, hard to disagree with that. “Zero di...
By Mars , 24 minutes ago
-
@bontwoody, I completely agree. I have to say, the le...
By Mars , 33 minutes ago
-
RE: Daikin 9kW to 8kW Swap Offer from Octopus
@matban I would have to check the CIBSE guide as we hav...
By ASHP-BOBBA , 56 minutes ago
-
RE: Ecodan Energy Monitoring Pack
Hi @carpenterstation Did you ever resolve the energ...
By CAMorgan , 2 hours ago
-
RE: is a home battery without an EV worth it?
I would find it difficult to justify a battery without ...
By Batpred , 2 hours ago
-
RE: What is the Heat Geek Guarantee?
Very useful post, one observation: I can see why instal...
By Batpred , 2 hours ago
-
RE: Widespread failure of insulation installation
And there are different kinds I guess. One fri...
By Batpred , 3 hours ago
-
@drei - there is definitely something not right, notwit...
By cathodeRay , 3 hours ago
-
RE: Octopus tariffs - a quick comparison
Great summary, @majordennisbloodnok! I'd take the ho...
By Batpred , 4 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@mike-patrick I'm no expert... but believe your ASHP is...
By Tim441 , 6 hours ago
-
RE: Renewables & Heat Pumps in the News
Good News from NESO released today which d...
By Transparent , 6 hours ago
-
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time
I agree with your last last sentence, but for another r...
By JamesPa , 6 hours ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
I spoke to the DNO (ukpowernetworks) about an installat...
By Batpred , 10 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Just wanted to share my experience with this kit, as I ...
By Batpred , 11 hours ago
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
@jamespa And then there was the window company I had...
By davidnolan22 , 11 hours ago