Vaillant's comment about de-icing is: It is hard to say how often a de-icing cycle will take place as it depends on several things…• The humidity of...
@richard24738 You had commented above that "I have today placed temperature probes on the buffer 4 ports. The top two pipe readings Primary in 40.0c a...
I recently bought some of those cheap digital thermometers with probes and have been using them to monitor the flow temperatures for the buffer tank i...
@transparent I've got some 5 minute data which includes the battery charge level. The increase in charge over the first 5 minutes of charging is about...
@transparent Further to my comment above, I contacted Tesla who changed the grid code in my Tesla gateway (battery controller) from G99 to G98 and the...
Vaillant have this comment about de-icing "The de-icing cycle will happen more often when the outside air temperature is around 2.5°C but will happen ...
The Vaillant Arotherm Plus specs refer to "Inrush current (with inrush current limiter)" which, I presume, manages this problem but perhaps other manu...
My 7kW Vaillant Arotherm+ heat pump has a maximum current of 15A according to the label. It should be sufficient for a very large new house that has b...
I normally see a steady increase in the sunny day peaks as January progresses. There's a link to my data below but I would note that my winter solar g...
Propane is denser than airso any leak is likely to spread laterally and not vertically. However, something else to watch out for is any airbricks in...
The lower you can get the flow temperature the better. If need be you can upgrade some of the emitters after getting some experience. Could you inst...
Octopus charged me nothing to remove my gas meter after my heat pump was installed and the boiler removed. The person who removed the meter said that ...
- 26 Forums
- 2,306 Topics
- 51.7 K Posts
- 149 Online
- 5,970 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
If you saw it with your own eyes I wouldn't attempt to ...
By AndrewJ , 8 hours ago
-
Our 7kW Vaillant is wall mounted, no problem neat insta...
By Judith , 8 hours ago
-
RE: Replacing my 18 month old ASHP
@trebor12345 @jamespa If it helps any this documents...
By RobS , 8 hours ago
-
RE: Cashback Incentives That Reward Shorter Ideal Heat Pump Warranties
Comment to bring this topic back into the spotlight for...
By Mars , 10 hours ago
-
RE: Maintaining temperature on windy day
I used to, but now I am retired. Mostly I miss doing th...
By cathodeRay , 10 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
Quick update, Solis AI looks like work in progress. Had...
By Batpred , 11 hours ago
-
@davidalgarve that sounds like the recommended method, ...
By F1p , 13 hours ago
-
RE: Extend the colder range of the weather compensation curve?
Daikin has a slope WDC which changes per degree of temp...
By RadWhisperer , 15 hours ago
-
RE: Why Millions of UK Homes Struggle With Heat Pumps
The idea (and at least one similar product) has been ar...
By JamesPa , 16 hours ago
-
RE: Getting the best out of a heat pump - is Homely a possible answer?
In a nutshell, yes- set weather compensation curve and ...
By benson , 20 hours ago
-
RE: Commencing on an ASHP Installation Process
@sheriff-fatman looks very nice. And good shout check...
By benson , 20 hours ago
-
RE: ECO4, ECO3, ECO2, ECO1, HUS, BUS, GBIS Dedicated Support and Advice
@toodles very happy too (I have no vested interest othe...
By Bart , 20 hours ago
-
-
RE: Boxt Heat Pump Installation Experience
By Andrew J H , 1 day ago
-
RE: Don’t Install a Heat Pump Until You Read This
I feel for you. I have never done a major 'build' per...
By JamesPa , 1 day ago
-
Threeway Diverter Valve question
I am looking at a few upgrades/fixes to my Grant Aerona...
By Grantmethestrength , 2 days ago
-
Thank you! I use plotly in python, with the data comi...
By cathodeRay , 2 days ago
-
RE: 10kw heat pump run in 24*7 data?
Vaillant are pretty good maintaining their ...
By JamesPa , 2 days ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
So this morning marked 24 hours up for installer. Rooms...
By Crimson , 2 days ago