Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JohnR
@johnr
Member
Estimable Member
Joined: Nov 25, 2024
Last seen: Apr 8, 2025
Topics: 0 / Replies: 106
Reply
RE: Could position cause a potential noise nuisance to me?

My cylinder, buffer tank and the hot water circulating pump are in a room underneath my bedroom (which has become noticeably warmer). There was audibl...

1 year ago
Reply
RE: Vaillant - Downstairs radiators not getting warm

That happened with my installation. Whoever had been sent to the plumbing suppliers to buy various parts got the wrong type of valve. Once the system ...

1 year ago
Reply
RE: Heat Pump starting current

I've done a quick analysis of data collected by a pair of Elitech RC5+ temperature loggers for the period 20 - 22 January to look for defrosting cycle...

1 year ago
Reply
RE: Vaillant Arotherm ASHP gets noisier when it gets colder outside

I very rarely hear my 7kW Arotherm+ but have twice heard it roar at the end of the defrosting cycle when it's blown out a cloud of fog. It's fitted un...

1 year ago
Reply
RE: Ideal Logic 10kW Heat Pump Pipes Noisy and Very Expensive to Run

@Ajbevster If the OAT is reading 10C high then it might be possible to offset this by setting the target house temperature as 10C high until the OAT s...

1 year ago
Reply
RE: Grant Aerona3 R32 HPIDI17 performance in low temperatures

@davidm06 I think 14C is better than 10C as it keeps a bit more heat in the house. I recall, without checking the documentation, that Vaillant defaul...

1 year ago
Reply
RE: Grant Aerona3 R32 HPIDI17 performance in low temperatures

At a house temperature of 10C there won't be much thermal energy in the circulating water to make defrosting quick and easy. I wonder if the heat pump...

1 year ago
Reply
RE: Ideal Logic 10kW Heat Pump Pipes Noisy and Very Expensive to Run

@jamespa: You might want to go easy on the abbreviations when someone is trying to understand how their heat pump works and may end up wondering why a...

1 year ago
Reply
RE: Heat Pump starting current

@transparent Amazon, for some reason, isn't cooperating with me today and 2 of the 3 links I have posted aren't working properly. Search Amazon for "E...

1 year ago
Reply
RE: Heat Pump starting current

@Alfapat: The inverter should provide the capability to ramp up the compressor speed but I notice that there is almost a factor of two difference betw...

1 year ago
Reply
RE: hum/whine from Wilo circulation pump

@Richard24738 Thanks for the clarification. I await your conclusion.

1 year ago
Reply
RE: Ideal Logic 10kW Heat Pump Pipes Noisy and Very Expensive to Run

Your system is worse than normal for something that has been very badly configured! My first thought is that you should turn up the radiator temperatu...