@CBrenewable @ashp-bobba seems to be on the case so I will step out for now to avoid possible confusion, name check me if you want me to step back i...
yes thanks! Im not sure I can really comment further as your key concern (unless I misunderstand you) seems to be the thermal offs which appear to b...
I cant immediately see anything wrong but I also cant follow the pipework. As you say this is a poor time to test/set things up, but I would still ...
Great. If you could post a picture of the area around the cylinder it would confirm that there is nothing untoward here.
Can you explain what you mean by 'off' please? If they are off how is that affecting the heat pump/circuits. If you are getting a SCOP of 3.5 what ...
@cbrenewable Hopefully the diagram shows one of the valves in the wrong place, otherwise there is a valve in the wrong place. Any idea why two pumps...
@trebor12345 Hi. What is it you are still trying to solve/understand. I will see if I can help. Definitely that is a 4 port buffer.
@CBrenewable A COP of 2.4 is definitely low and you are right to be concerned. You should be seeing 4 or better at present. Can you tell us s...
Have you got the loss calculations, if so perhaps you could post?
The output of a rad is proportional to DT to the power 1.3, where DT is the average temperature difference between rad and room. At a flow temperatu...
Just to clarify this was a serious question, its going to be easier to explain your observations above if you have plots. If you dont then just say a...
- 26 Forums
- 2,265 Topics
- 50.6 K Posts
- 492 Online
- 5,924 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: My DIY Heat Pump installation
@polar-bear So from your diagram I see that you are usi...
By bontwoody , 12 minutes ago
-
Great idea. TOU includes Agile (mirroring wholesale)...
By Batpred , 14 minutes ago
-
RE: Electricity price predictions
So he must have a good team helping him in this.. ...
By Batpred , 1 hour ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Gone with Fernox Alphi-11, relieves the installers conc...
By Crimson , 3 hours ago
-
RE: Midea ASHP – how to set weather compensation
I can't do it for a Shelley device, but I can for Eastr...
By cathodeRay , 3 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
There is no such thing as a silly question! @toodles ...
By JamesPa , 4 hours ago
-
RE: UFH downstairs and radiators upstairs balancing question
Isn't this a great example of KISS!
By JamesPa , 5 hours ago
-
RE: Who has a V2G EV installation
Would that be a Chint RCD perhaps? Have a look at thi...
By Transparent , 5 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
11.2kW Ecodan Manufacturer: Misubishi Model: PUZ-WM...
By DRB01 , 18 hours ago
-
RE: Homely asking about Solar Panels.
@majordennisbloodnok I will report back with any develo...
By Toodles , 21 hours ago
-
RE: Mediation with RECC, what's your experience?
@editor Thank you, I really appreciate it! I've made ...
By TreeWizard , 23 hours ago
-
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
Are you able to post a photo of that 180-litre cylinder...
By Transparent , 1 day ago
-
Agreed. It doesn't take all that much maintenance to ke...
By Majordennisbloodnok , 1 day ago
-
RE: Oil Boiler & Heat Pump Hybrid System
OK. Got it. As a fellow rural West Country resident, ...
By Transparent , 1 day ago
-
RE: Flexi-Orb Heat Pump Scheme: A Game-Changer for the UK's Heat Pump Industry
Ok so that seems to be the key point namely only mcs ca...
By JamesPa , 2 days ago
-
RE: One flow valve appears to be duff
You might want to consider the following common faults:...
By IaAck , 2 days ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
We are on the Intelligent Octopus Go tariff. We instal...
By GrahamF , 2 days ago