Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 19, 2026
Topics: 27 / Replies: 5268
Reply
RE: Hitachi Yutaki M efficient operation

... which is probably its min output. At 12C you would expect cycling even if the pump was right sized, it gets colder later this week so i suggest r...

2 years ago
Reply
RE: Hitachi Yutaki M efficient operation

That will be the water pump capacity not the heat pump capacity, which is dependent on the house loss. The water pump may be on longer than the heat...

2 years ago
Reply
RE: Hitachi Yutaki M efficient operation

That's disappointing. It's way oversized almost without any doubt. 6kW is probably nearer the mark, possibly less. I will re-read your description...

2 years ago
Reply
RE: Hitachi Yutaki M efficient operation

@iraknic Ok I was hoping 6 was 6kW not 6 tons (an American measure of capacity roughly equal to 3kW). I suspect it's well oversized. What do y...

2 years ago
Reply
RE: Hitachi Yutaki M efficient operation

I am not familiar with the Hitachi monitoring so someone else will need to answer this. If you can monitor power consumption it will be visible in th...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

@transparent @sicky Just a couple of observations 1. Sadly I would say the standard of work is exactly what one expects, this is either the b...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

Im not an expert by any means but, in the absence of any detail to the contrary, buildings are normally built to the standards required by building re...

2 years ago
Reply
RE: non-Mitsubishi owners - how much control do you have over your ASHP "freeze stat" function?

For me the sole purpose of the glycol or antifreeze valves is to provide backup protection if the power fails for any length of time; the freeze stat ...

2 years ago
Reply
RE: Placing objects next to an outdoor air source heat pump unit – what are the rules?

Most heat pumps have specs on minimum clearances, perhaps check this. That said I agree with @transparent that an open frame construction would be ...

2 years ago
Reply
RE: Hot water tank losing temperature quickly: Daikin Altherma 4kW

Agree. I changed mine because I reheat only once per day, which is fine so long as hysterisis set too high cause it to skip a cycle. However you see...

2 years ago