Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 8, 2026
Topics: 27 / Replies: 5468
Reply
RE: Ideal HP290 14kW ASHP - how to optimise

Sorry to hear that but not surprised. I am pretty sure this is a rebadged product which Ideal wont understand in depth, which is a pity because their...

9 months ago
Reply
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer

Further to the post above I have now worked out (I think) 2 port buffers. The conclusion is, just like 4 port buffers - avoid. Here is the explanat...

9 months ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

The question is, what is 'the latest method of calculation'? Here are two relevant extracts from MIS3005-D which point to the answer to that question...

9 months ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

How is the figure measured, specifically is it a measure of it passive infiltration or an artificial measure with a pressure that is greater than woul...

9 months ago
Reply
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer

Noted and dilemma understood. A volumiser may not be needed but it wont do any harm if its plumbed correctly. As it is, its a 2 port buffer and may ...

9 months ago
Reply
RE: Ideal HP290 14kW ASHP - how to optimise

The sad fact is that you have to check everything some installers and maintainers do, or alternatively hover over them whilst they do their work. In...

9 months ago
Reply
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!

@razz You should perhaps take a look at and interrogate this A Cosy owner who has solved excess noise problems with some very simple DiY case mods.

9 months ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

You are lucky they have used 0.5, many surveys use 2-3. With a very low loss home air changes (unless you have MVHR) are going to dominate, they are ...

9 months ago
Reply
RE: New Solar, Batteries, Air Source and Under Floor Heating advice please

Welcome to the forum and please feel free to ask any question you wish.   Here is my starter for 10 focussing on the ASHP   12kW s...

9 months ago
Reply
RE: Ideal HP290 14kW ASHP - how to optimise

Since you ask what others think, I think he is very probably talking rubbish and doesn't understand how ASHPs, or indeed weather compensation, works. ...

9 months ago
Reply
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer

In the diagram the volumiser is shown as being between flow and return thus acting as a short circuit for the water flow. This is wrong, it should ei...

9 months ago