Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 11, 2026
Topics: 27 / Replies: 5224
Reply
RE: Grant ASHP 17.5 kw. weather curve

@chinkoa   Sorry there are two separate thoughts going on which I didn't make clear:   "What's the capacity of the heat pump. Flow...

7 months ago
Reply
RE: Radiator sizing sanity check

Agree. I think I have given you several pointers to help track it down, its now up to you whether to pursue any or hope your installer will diagnose,...

7 months ago
Reply
RE: Radiator sizing sanity check

@papahuhu sorry - confusing info in previous posts Anyway upstairs rads aren't getting to anything like the flow temp it seems so that needs to be f...

7 months ago
Reply
RE: Grant ASHP 17.5 kw. weather curve

What's the capacity of the heat pump. Flow rate (l/s) x DT (say 5) x 4.2 = heat transferred in kW which needs to be greater than or equal to capacity...

7 months ago
Reply
RE: Radiator sizing sanity check

I find it impossible to believe that your house heats by 0.7C, or even 0.2C, in 2 minutes, unless you live in a tent. IMHO something else is causing ...

7 months ago
Reply
RE: Radiator sizing sanity check

That really, really shouldn't happen and suggests that the heat pump may be well oversized or there is some other problem eg a badly set up buffer/LLH...

7 months ago
Reply
RE: Cascade 2x Grant Areona 10kw ASHP - Ongoing setup issues

Either complete Bow Locks or at best a marginal effect. The amount of energy it needs to produce is fixed by your house. If you force it to produce...

7 months ago
Reply
RE: Radiator sizing sanity check

Are you saying that there is a loss of 8C from heat pump to rad. Thats a lot - why? If thats right then its not surprising rads are too small! &nb...

7 months ago
Reply
RE: Radiator sizing sanity check

Air comes out of solution over time. I had to bleed one radiator every second day for a month after the installation was done and only the other day ...

7 months ago
Reply
RE: Cascade 2x Grant Areona 10kw ASHP - Ongoing setup issues

I presume he didnt say why? I dont personally understand how this can be the case (so suspect BS) but of course willing to listen to arguments. &nb...

7 months ago
Reply
RE: Radiator sizing sanity check

Well that puts a different light on it altogether! Radiators not getting warm would be due to one or more of (a) valve blocked - note that TRV pins...

7 months ago
Reply
RE: Water Hammer After Heat Pump Install

@jaynieq I wish you luck with this one. I think the main thing I am telling you is to focus (when discussing with any plumber) on the water hammer an...

7 months ago