Frenchmen, Germans and Blushing Heat Pump "Engineers!" Over the past two years, visiting "Engineers" have produced the most extraordinary comments...
Heat Pumps: Hypothermia & Bankruptcy Having spent ~£14k on a Heat Pump I am now , a 76 year old , Am I Now faced with Heat Pump Hypothermia ?: ...
Is my Heat Pump Too SMALL for Winter AND TOO BIG for Spring? My Heat Pump does Not supply ENOUGH Power HEAT DURING Winter . -- Attachment is not ...
Measuring Cycle and Run Times on a Heat Pump I record the Power Consumed by my Heat Pump on a Daily basis. For example , on 30 th March I get:...
My Heat pump REAL COP ( that measured at the start of the Radiator pipe circuit ) and Heat Pump COP ( as shown by the Heat Pump itself ) are for 28/29...
Design & Measurements of Heat Pump Performance? Wall Thermal Conductivity, U ...............abuse ? Given my own experience, where my "instal...
@editor Why can't Heat Pumps be Mathematically DESIGNED and tested using a program like H2X ?? Buffers as Batteries? With the introduction of Ti...
@editor All Modern Heat Pumps use an Inverter to control Heat Pump Water Power. All modern Heat Pumps have a Minimum Power BELOW which the HEAT PU...
@editor All Modern Heat Pumps will Cycle when operating BELOW the Minimum Inverter Power . Here is a detailed graph of the Power my Heat P...
@editor Heat Pumps ............Short Cycling Older Heat Pumps 1) In all older Heat Pumps the Power was controlled and regulated by binary sta...
@editor To Buffer or Not ? The following jpeg is taken from Kensa: The Docx is given from Kensa : An extract from Kensa : What’s the...
@Mars COP & REAL COP My Samsung Advertises it's Coefficient of Performance, COP on the "Energy Consumption" and "Energy Generated" Displa...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 51 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time
I think you said you have a buffer. Is it the primary ...
By JamesPa , 12 minutes ago
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
Er...no comment!
By JamesPa , 21 minutes ago
-
RE: 4 Year Ongoing Heat Pump Battle With Poor Heat Pump Installation
@fiona sorry to hear that, and I sympathise with you be...
By Mars , 43 minutes ago
-
That’s exactly my point. Kit and equipment fails, but t...
By Mars , 46 minutes ago
-
Um, not accurate, I’m afraid. CCS type 2 connectors a...
By Majordennisbloodnok , 52 minutes ago
-
RE: Samsung Heat Pump – Can't Activate TW2 Pipe Sensor (for Delta T Control)
If you do suggest you consider repurposing it as a 2 po...
By JamesPa , 11 hours ago
-
RE: Say hello and introduce yourself
Fully agree with @cathoderay. My journey took 2 years ...
By JamesPa , 12 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
Tim, Yes ChatGPT thought I could get another...
By Mike Patrick , 21 hours ago
-
RE: Enabling WiFi: Samsung ASHP on Smart Things App
No problem, @richdorm; glad it helps.
By Majordennisbloodnok , 23 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
If that makes you feel happier then go ahead, but it wo...
By JamesPa , 23 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
I do already have the same basic setup, all room influe...
By cathodeRay , 24 hours ago
-
RE: IVT Greenline high pressure switch and electrical cassette errors
OK. You dont say whether it is from the feeds to/from ...
By JamesPa , 1 day ago
-
RE: How can I programme a setback for my Samsung Gen6 8kW heat pump?
Yes, and probably also Adia although the latter has a m...
By JamesPa , 2 days ago
-
@editor I am all in favour of provocati...
By GrahamF , 2 days ago
-
RE: How to Understand Wiring Up a Heat Pump
Morning, On top of what everyone else I would deffo loo...
By Grantmethestrength , 2 days ago
-
RE: Sizing a heat pump: Save me from my headache
Got the results back from the one we’re ...
By Mikeatthezoo , 2 days ago