Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

iantelescope
@iantelescope
Contributor
Reputable Member
Joined: Mar 29, 2023
Last seen: Apr 29, 2025
Topics: 1 / Replies: 417
Reply
RE: My horrific Samsung heat pump installation and experience

@jamespa Could I try and express my problem in a different way? All heat Pumps have a Maximum power output , in my case ~5 kW. All Heat ...

2 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

What is the purpose of Field bit 2091/2/3 Water Pump 3 option on Samsung Heat Pumps: I asked a visiting Samsung engineer: "What is the purpose of...

2 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@richard24738 Hi Richard. "Short Cycling, causes and cures" My Heat Pump has been "Short Cycling " since installation in July 2022 resu...

2 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Hi Richard, Re: Temperature Measurements: Water Meters: Water Meters are the best method to measure the water Temperature within a pipe. ...

2 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Heat Pumps ..................What a Sad industry. "Happy with a Heat Pump installation"...............I would wait a wee bit . I was "Happy " ...

2 years ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

I have been watching, with interest, the rebuild and replacement of a five year old Heat Pump on the Skillbuilder site. The Results of the rebuild d...

2 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@jamespa I must apologise to yourself for my Scottish Scepticism. Many thanks James, Believe me when I say I Appreciate your response . So...

2 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@editor Attacking other "experts" Does NOT inspire confidence! Heat Pump Thermal-Syphoning My Samsung 5kW Heat Pump , now in it's second Sprin...

2 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

" Short Cycling", Thermal-Syphoning My Heat Pump displays "Short Cycling": The Standard Solution to "Short Cycling is the use of a Buffer Tank :...

2 years ago
Reply
RE: Samsung's Cold Shoulder: Should Heat Pump Manufacturers Be More Accountable?

Samsung's Reputation? My Samsung Heat Pump was , initially "installed" without an Expansion Vessel, Flow Sensor , Thermostat OR PRV . The Flow Se...

2 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@editor " A heat Pump OR an Oscillator ?" " Four Pipe Buffer Tanks OR Volumisers" My Heat Pump continues to Oscillate or "Short Cycle " : T...

2 years ago