Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

iancalderbank
@iancalderbank
Contributor
Prominent Member
Joined: Oct 17, 2022
Last seen: Jan 14, 2025
Topics: 0 / Replies: 643
Reply
RE: A Beginner's Guide to ASHP Monitoring

@cathoderay I just think that you've perhaps got a bee in your bonnet about HA and the sleepless nights its caused you and conflated matters..sorry, n...

3 years ago
Reply
RE: Vaillant flow rates, Delta T, buffer sizing - trying to get ASHP running well but hit a brick wall.

@sunandair yes . your diagram is exactly what we are suggesting to the OP should be their target state - to be reached when a decent period of system ...

3 years ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

@transparent yes, fair enough and I agree with you. my point is only that switching to 5Ghz on the wifi side is a better option if technically possibl...

3 years ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

surely better advice would be to upgrade your home wifi network and devices to a 5GHz system. anything since Wifi 5 a.k.a 802.11ac released 2014 is 5G...

3 years ago
Reply
RE: Vaillant flow rates, Delta T, buffer sizing - trying to get ASHP running well but hit a brick wall.

your system as built has a minimum circulating volume of 45L. i.e. just the buffer. so that must be the min vol needed by vaillant. In your system its...

3 years ago
Reply
RE: A Beginner's Guide to ASHP Monitoring

@cathoderay if you've set a reserved IP address for the HA machine, using the DHCP configuration page of your router, then that will take care of it f...

3 years ago
Reply
RE: PV Inverter Experience/Advice/Support

there are probably better forums than this one for solar inverter trade offs. One thing to be aware of with string inverters - they assume all panels ...

3 years ago
Reply
RE: PV Inverter Experience/Advice/Support

@transparent I have pretty similar setup. I'm happy to push the Octopus (Intelligent in my case) window to the edge though (2330-0530). there's no sim...

3 years ago
Reply
RE: A Beginner's Guide to ASHP Monitoring

if you get static IP's wrong its a disaster. Stuff won't work and you can spend hours trying to figure out why . You must separate your network so tha...

3 years ago
Reply
RE: Vaillant flow rates, Delta T, buffer sizing - trying to get ASHP running well but hit a brick wall.

yes. hanging on till the summer for a reinstall sounds like the right option. Although make sure you understand exactly what company #2 are going to d...

3 years ago
Reply
RE: Vaillant flow rates, Delta T, buffer sizing - trying to get ASHP running well but hit a brick wall.

@squonk run the system in DHW mode and with your thermometers, see if the water going through the diverter valve, on what should be the Hot input to t...

3 years ago
Reply
RE: A Beginner's Guide to ASHP Monitoring

@cathoderay the beginners commentary for HA , if it was to be written up as a full end-2-end solution , would need to include things like IP addressin...

3 years ago