Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 14, 2025
@editor my point is really that you said you used Xkwh - but that was the whole house - you have no separation for heat. without that its meaningless ...
do you monitor your COP or heat energy output ? or meter the HP separately? I think you need to have that to be able to talk numbers. I know you are...
all that data you ask for is in the feeds that are uploaded to heatpumpmonitor.org by multiple systems. if you were to post this on openenergymonito...
WC and flow temps - main thing is that they set WC , but also give you instructions on how to change it. likely scenario is that if they set it at all...
@dunlorn yeah it should be perfectly possible to treat them just as independent heat sources, decouple the master-slave, if send them both a call for ...
IMO the only vendor independent system of monitoring is to put in a heat metering setup and link it to openenergymonitor. I've nothing against modbu...
@dunlorn I was just pondering a possible idea for you: you could take control of each heat pump individually via modbus, run them as 2 separate rather...
@dunlorn would it be feasible to individually control your two units rather than rely on samsung's master slave behaviour?
@dunlorn FWIW, I was running at about 9kw also on saturday (-2C here all day), flow rate of 28l/min , that kept us at 21C inside . pretty sure that i...
static head isn't relevant, the water goes round in a circle, what goes up must come down. What matters is the resistance to dynamic flow. Given that...
mine for the 29th, max 3C day then -2 at night. 41kwh of electricity for 110kwh of heating. short-term COP is nearly 3 when it stable running in heati...
a few of us here are on that monitoring platform. I'm the "milton keynes samsung 16kw" one. direct link to mine's in my sig.
- 26 Forums
- 2,610 Topics
- 60.8 K Posts
- 272 Online
- 6,967 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Anyone concerned about GivEnergy?
Yes and no. Native controllers generally do a good jo...
By Majordennisbloodnok , 8 hours ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
@temperature_gradient I've had air-to-air for just over...
By Anne Smith , 13 hours ago
-
RE: Home automation and the cloud; is there a better way?
+1 It's not just cloud though. Many devices have repla...
By bobflux , 14 hours ago
-
RE: End-of-Life Heat Pumps: How Do You Dispose of an ASHP in the UK?
We've started to document everything, and part 2 of the...
By Mars , 19 hours ago
-
RE: Summer usage. Why is my Vaillant Aerotherm using so much energy on "heating"?
So the red bars are 'DHW' and the yellow bars 'heating'...
By JamesPa , 20 hours ago
-
Its good kit the Midea and significantly cheaper, you w...
By ASHP-BOBBA , 24 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Have you tried cutting the grid feed to see what actual...
By JamesPa , 24 hours ago
-
Contractors pack for inta antifreeze valves are around ...
By ASHP-BOBBA , 24 hours ago
-
RE: Renewables & Heat Pumps in the News
Critics and naysayers will be negative whatever the gov...
By JamesPa , 24 hours ago
-
RE: Microbore heat pump installs
In principle you are almost certainly right, but in pra...
By JamesPa , 1 day ago
-
RE: Electricity price predictions
@old_scientist We are a low mileage home, so bulk of ou...
By ChandyKris , 1 day ago
-
There are just too many unknowns for me to comment on p...
By Transparent , 2 days ago
-
RE: What is the main ‘dictator’ of Agile’s unit price?
@toodles I keep an eye on wholesale prices and energy m...
By ChandyKris , 2 days ago
-
RE: Brand and installer questions for ASHP
Strange, perhaps it doesnt use modbus which the third p...
By JamesPa , 2 days ago
-
RE: Upgrading my system, how far do I go?
For comparison, my PW3 with 11.04kW inverter, will char...
By Old_Scientist , 2 days ago
-
RE: Changes to Tesla Powerwall Charging Regime?
Elon gate - legendary! I take my hat off to you @toodle...
By Old_Scientist , 2 days ago
-
RE: Mitsubishi Ecodan not good enough ?
Thanks @goody, appreciate the feedback and sorry you ha...
By marcexec , 2 days ago
-
RE: Minimum and Zero Disrupt Heat Pump Installations
True (first sentence) Thats the reason to consider th...
By JamesPa , 3 days ago
-
RE: High air source heat pump running costs – Vaillant AroTherm Plus
Quite right. I was using a rough guesstimate of doublin...
By Majordennisbloodnok , 3 days ago
-
RE: My Grant R290 9kW Heat Pump Installation
Again, really don't know how accurate this is! &nb...
By petch , 3 days ago
-
RE: MCS Quality Audit – Has Anyone Had One? Did It Lead to Remediation?
@toodles The whole scheme is a shocking waste of money....
By Papahuhu , 3 days ago
-
RE: DIY or Don’t Touch? Solarman Smart Meter Install
Yes, and these guys would probably be my preferred inst...
By Batpred , 4 days ago
-
RE: Hot water tank lose heat rapidly on random days
@jamespa Hopefully their reasons are well intended! ...
By Bash , 4 days ago
-
RE: Ecoflow UK Support & Info Thread
As mentioned above, we’ve got our full review of the Ec...
By Mars , 4 days ago