Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

iancalderbank
@iancalderbank
Contributor
Prominent Member
Joined: Oct 17, 2022
Last seen: Jan 14, 2025
Topics: 0 / Replies: 643
Reply
RE: ASHP User Interface gone blank

not a massive surprise. if the external unit has power but no comms to the internal unit, and it knows that its "cold out", one might reasonably suppo...

2 years ago
Reply
RE: Defrost Cycles - How Common Are They?

I think you'll find it quite hard to tell based on either poking radiators, or long term data. There are lots of spikes in the "HP temperature" that ...

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 its not that exciting... you can't not have one ! they're absolutely standard required items , your system wouldn't work at all without o...

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 an air vent looks something like this and will be at the top of any high points in the pipework . definitely should be one around your...

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 PP will just be running slower, thats why its gone quieter. check your flow rate, it may be lower than you want.

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 so they've used the proper method as far as I can tell to get out the garage wall to the ASHP (big hole, insulation through hole, pipe t...

2 years ago
Reply
RE: Is the Samsung Gen 6 12kW AE120RXYDEG ASHP right for me?

@tobyg the vast difference between your gas usage and their estimate is a significant concern. also, a gas boiler is at best 85% efficient. so your me...

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 yes although that is interior grade insulation. It needs to be exterior grade thickness in any unheated space, so the easiest it just to ...

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 no worries. copper pipe will transmit vibration to any hard surface its in contact with, particularly one carrying a high flow rate such ...

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 for the run under the floor inside, the pipes need moving further apart so there is room for interior grade lagging. they may possibly ne...

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 28mm pipe : thats good. but I can see the issue. the pipe goes through a hole in breeze block thats only just bigger than the pipe . wi...

2 years ago
Reply
RE: ASHP flow through pipes is noisy and preventing us from using at night......looking for help.

@dannymoss23 noise: so seems like you have 2 pumps a primary-side and a secondary-side. which is common. I wouldn't expect there to be a 3rd one. ...

2 years ago