Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 6, 2025
We found that swapping out heated towel rails for dedicated bathroom radiators made a huge difference as they actually give off heat instead of retain...
We also fitted a surge protector on the main board at the recommendation of the plumber working on our extension as he worked on a job where someone h...
Has the ASHP been checked to see if its repeatedly going into antifreeze/frost protection mode? I had a period of time with our Mitsubishi ecoda...
Have LG confirmed what size ASHP is suitable? Do you have access to the system data showing flow rates/temps etc? It would be interesting to see...
Yep that was my review 🙂 I think our ASHP is probably under sized for our property but as we are south west facing and have lots of rear glazin...
The EPC states 418M2. Our hot water usage is much higher than average as we usually have 7 people living here and in the last year we had 11 peo...
Have you considered fitting an auto refill valve to keep the system topped up and pressurised?
We use Heatmiser Neo thermostats for all of our downstairs underfloor heating and the Honeywell Evo system upstairs for our radiators that works reall...
I've attached the performance data for our 14kw Mitsubishi Ecodan ASHP. All data used is from the units software/controller so I can't confirm how acc...
The EPC system is a bit of a farce. I'm aware of people who issue some EPC's without even visiting the property 🤣 There is a massaging o...
We had our ASHP serviced for the first time in December 2020 - roughly one year after installation. I would like to have used the installer but ...
Our 14kw Mitsubishi Ecodan ASHP and 500l cylinder was installed by Artizan Heating/Lifestyle in 2019. I dealt directly with the Owner Michael wh...
- 27 Forums
- 2,811 Topics
- 66.5 K Posts
- 2,298 Online
- 7,217 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Why don't people choose heat pumps?
It's swings and roundabouts - during off-peak periods t...
By Temperature_Gradient , 40 minutes ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
... And that's being generous! I'll tell you a littl...
By SusannaSaunders , 7 hours ago
-
RE: Adding data centre electricity costs to domestic energy bills?
never ceases to amaze me.. Keeping steel works going ...
By Batpred , 8 hours ago
-
RE: Electricity price predictions
great session Reminds me why some politicians can be ha...
By Batpred , 8 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Absolutely agree. The massive Hager CU my vaillant requ...
By Batpred , 8 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
absolutely agree. even if many providers see that extra...
By Batpred , 8 hours ago
-
RE: Octopussy cosy 6 experience
People who have a Cosy appear generally to be happy wit...
By JamesPa , 12 hours ago
-
I thought the cr*p came first and the biofuel came afte...
By Majordennisbloodnok , 16 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 2 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 4 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 4 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 4 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 5 days ago