Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 27, 2026
It would explain the difference between different heat loss assessments, so the person doing it, will most likely be either accurate enough, or overes...
I wanted to provide an update in regards to the insulation visit today, which may prove relevant to heat loss assessments. He used cameras to look i...
That's my main concern too. On top of that, I had someone come over today to check the insulation on this 2004 property. We looked inside the...
Would you say try and specc each room by around 10% to 20% uplift and if not possible make it up in other areas? With us, the whole ...
Yep that's it, but the current design would require either tall vertical 2000 or 2200 mm K2 rads, or larger 900 mm tall K3. I was just wonder...
I guess you didn't see my original post and the article 😋 😉. I have a pretty accurate maths formula that can churn out the re...
Floor plans with radiator and heat pump locations and the doors stay open, the kitchen doors are kept about half way open, to allo...
These sound the same as the Jaga units @downfield mentioned in another post. If they work then I am definitely tempted, issue is that I have no electr...
I've created a separate post here, wondering about radiator sizing, if anyone is still following this post:
On the subject of heat loss. Today I called an Essex based company called Dynamic Insulation, mentioned that I had a heat pump installed and my house ...
OK so from what I see now, the fans look similar to fan units used in data centres on servers, routers, network switches, storage device etc....
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,958 Online
- 7,157 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Cooling with air to water heat pumps
A quick update. I finally found a 'solar' roller bli...
By springswood , 33 minutes ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
85kWh of gas usage, divided by 24 gives 3.54kW and adju...
By Old_Scientist , 1 hour ago
-
New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
I am feeling baffled and worried:We are having a an Aro...
By GutoFfowc , 12 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 15 hours ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 15 hours ago
-
RE: Questions about A2A for heating as well as cooling
@donciccio I would suggest that you take a "fabric-fi...
By Rob of York , 15 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 1 day ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 2 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 3 days ago