Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
If you would care to provide the minute by minute raw data for last nights chart, I will run it through the Modeling Tool as see if it predicts that c...
@cathoderay I would state that last nights cycling was due to the weather being milder, hence the heat demand was below the minimum output of the he...
@cathoderay What was the operating mode of the heat pump?
I will make one final attempt. But your heat pump controller does know the true OAT shortly after it has stopped running, the problem being that it ...
It means that I don't have a problem if you wish to keep going round in circles.
The WC curve needs to match the heat loss of your home. What is the heat loss calculation? When heating the hot water cylinder, the heat pump increa...
@cathoderay No problem.
What are the settings of the Weather Compensation (WC) curve?
Okay, time to go back to basics. What is the size and type of your home? What is the heat loss calculation for your home? What is the output capacit...
That is the reason why I suggested putting the system in fixed LWT mode for a period of time, it is similar to putting an auto control system into man...
@cathoderay What is the 'source' of the Set LWT reading? Is it read from the Midea controller? I wonder if the controller waits until the LWT has ...
So you are the culprit behind NG (or whatever they are called, or going to be called) having to carryout such excessive upgrades. 😋
- 27 Forums
- 2,815 Topics
- 66.7 K Posts
- 2,335 Online
- 7,230 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
Wow, an appliance can be smarter than the manufacturer ...
By Batpred , 1 minute ago
-
RE: DIY powerflushing tutorial
My tap water is 26.5°f (French hardness degrees) which ...
By bobflux , 6 minutes ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
@editor And as an occasional contributor, may I say wel...
By Toodles , 2 hours ago
-
RE: Should Households Who Can Afford It Pay More for Energy to Help Those Who Can't?
They don't have to try. Our entire system is d...
By EtchedPixels , 2 hours ago
-
RE: Why don't people choose heat pumps?
Fair enough. I guess I was thinking of pipes that run ...
By JamesPa , 2 hours ago
-
RE: How Can I Prove Coal Was My Main Heating Source Without Receipts?
Got excepted for the grant now so thanks for the replie...
By Chilli304 , 6 hours ago
-
Daikin Altherma 3 R F+W, room thermostat control, weath...
By JanHarley , 7 hours ago
-
RE: Buffer tank on a 2 x 14kw Ecodan system
Pretty much as I had guessed in my crude scaling from m...
By JamesPa , 10 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
Well you have a vibration generator running at some fre...
By bobflux , 24 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@downfield Thats a decent rate, I’m shocked they hadn...
By Papahuhu , 2 days ago
-
RE: Adventures in heat loss calculations
@toodles thanks! So as suspected, around a doubling of ...
By SusannaSaunders , 2 days ago
-
Six books in three years and I think I’ve now covered j...
By Mars , 2 days ago
-
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey
@heymikey Well done in achieving as nearer a match acro...
By Toodles , 2 days ago
-
Grant Aerona - Weather Compensation and Schedules
Im trying to set up a friends Grant Aerona. The WC curv...
By bontwoody , 3 days ago