Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
Hi Benseb, Just as a car engine has a minimum speed, so does a heat pump. What is probably happening is that your thermostat, if you have one instal...
@iancalderbank As I stated previously I remember reading that at least one of the controllers allowed the required DT to be set greater than 5. Unfo...
Hi Mars, It is my understanding that WC sets the WFT dependent upon the programmed curve and the outside temperature. You may therefore get variatio...
Heat pumps do not work particularly well with thermostat control, which is on-off. Most if not all of the modern heat pumps incorporate weather compen...
Hi Brooster, Welcome to the forum. Batalto is perfectly correct that a thermostat is not the ideal method of controlling an ASHP. The Mitsubishi C...
I would have thought that the opposite would actually occur. Consider the following. A heat pump is running happily with a Water Flow Temperature (W...
@iancalderbank There are some heat pump controllers which allow the required DT to be set to a particular value, within a specified range. Have a lo...
@editor Probably try 1 or 1.2 first and see how your system performs.
If wholesale gas price, as the graph shows, is 236.28p/Therm, this equates to 8.062p/kWh. A Combined Cycle Gas Turbine (CCGT) Power Station is approxi...
@julianc Try turning up your Nest to remove it from control. During Spring and Autumn you will still probably get some cycling even on weather con...
@jeff I think that Transparent pointed out in previous posts, that in his particular area, many of the grid upgrades would not be necessary if there...
@prjohn I worked in the Electricity Supply Industry when it was privatised. It wasn't long after privatisation before the 'bean-counters' started ...
- 27 Forums
- 2,745 Topics
- 64.5 K Posts
- 935 Online
- 7,148 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
I'm asking the same question. For me I want something ...
By JamesPa , 27 minutes ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu Of course, in the way of such things, there a...
By Toodles , 5 hours ago
-
@DavidB, I think @Majordennisbloodnok has already naile...
By Mars , 1 day ago
-
RE: Indevolt Batteries UK Support & Info Thread
Thanks, however that's an answer to a subtly different ...
By JamesPa , 2 days ago
-
RE: Flushing system, cleaning and inhibitor
Yes, my 50L volumiser uses the two lower ports, so ther...
By Old_Scientist , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Such elegant symmetry. look at my lumpy bag of...
By Papahuhu , 3 days ago
-
RE: PV and battery long payback - sense check query
Quite probably not, but you can get a 32A relay and a S...
By JamesPa , 3 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s Look forward to making contact soon! Regards, To...
By Toodles , 3 days ago
-
I don't notice mine defrosting, and most of the time Im...
By JamesPa , 4 days ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Kind of you, @calumm, but it was @f1p who did the heavy...
By Majordennisbloodnok , 4 days ago
-
RE: Electricity price predictions
2. As EV ownershp increases it'll certainly increase de...
By EtchedPixels , 5 days ago
-
I meant to say I cannot register my kit at Energyplus… ...
By Batpred , 5 days ago