Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@tufty I suspect the main item that would likely be damaged would the the condenser, which is a Plate Heat Exchanger (PHE). Whilst I don't think tha...
No. But not having a wood burner may have something to do with the decision. For some reason 'she who must be obeyed' frowns upon me trying to build a...
I have no idea how long it will take or the likely cost. I have an A2A heat pump which doesn't require anti-freeze.
@bontwoody There are quite a number of aspects to consider when it comes to the sizing of a heat pump. As James has correctly pointed out, the sta...
@tufty I suppose that this is one of the grey areas, where one would hope that the engineer would at least explain the meaning of the -4, before he ...
Where did you get the data for the Ecodan? According to the manufacturers data at an OAT of -7C, the 11.2kW Ecodan has a capacity of 10.6kW at a LWT o...
@jamespa Hi James, I have now completed some further improvements to the modelling tool. It is now possible to adjust the desired IAT setpoint a...
@crustydoodle The installer is responsible to provide you with a proven functioning system, failure to do so would be a breach of contract. I would ...
From the noise point of view I seem to think that the water pump is being supported by the pipework. The pump should be mounted on a suitable bracket ...
@redzer_irl You could try running the heat pump in fixed LWT mode starting with a low LWT setting and gradually increasing the setting until the des...
@crustydoodle Just to clarify if my understanding is correct. You started the heating system by raising the setting on one or more thermostats. Th...
Yes, the sensors are the thermistors. When I refer to 'good thermal contact', I mean is the thermister either fitted in a suitable pocket or clamped...
- 27 Forums
- 2,800 Topics
- 66.2 K Posts
- 3,005 Online
- 7,206 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: New Build 3 Phase or 1Phase
@e-a-west Given that your new build is 144 sqm and that...
By Rob of York , 2 hours ago
-
RE: How will removing the standing charge on gas bills benefit heat pumps?
I'm not sure it makes much of a difference to heat-pump...
By Temperature_Gradient , 13 hours ago
-
@editor Ouch, sorry to re start the tick. I had assume...
By DavidB , 14 hours ago
-
RE: Say hello and introduce yourself
@e-a-west as the good Major said, welcome to the forums...
By Mars , 15 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
Yes I actually have a copy of a tool that whenever a ce...
By EtchedPixels , 1 day ago
-
RE: Indevolt Batteries UK Support & Info Thread
@editor Hi, To resolve this, please tap on the A...
By Indevolt Tech , 1 day ago
-
RE: Double or Triple Glazed Windows?
Posted by: @singlespeed With 9 years repairing windo...
By Rob of York , 2 days ago
-
@transparent we’re still running a secure version of PH...
By Mars , 2 days ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
Much longer than that here. The heating isn't even on. ...
By bobflux , 3 days ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
Obviously the weather is changeable but there's a defin...
By Singlespeed , 3 days ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@rob-of-york I must admit that when we had a Daikin hea...
By Toodles , 3 days ago
-
RE: Forum updates, announcements & issues
Get the Renewable Heating Hub heads-up on WhatsApp. I...
By Mars , 3 days ago
-
RE: Safety study for plug in batteries out to tender - looks like Q3 2027 at best before legal
@editor I pointed out to the one of the Fuse execs that...
By dansus , 3 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews As well as loft insulation, there are othe...
By Rob of York , 3 days ago