I believe this is in reference to what they originally designed which was as an example: A Stelrad Concord Lo-line 296x1600 v A Eskimo 200x1694 ...
Thanks Toodles, this is the ongoing back and forth unfortunately with the builder, plumber and now heat specialist. According to the builder the heat...
Hi both, the rads heat when the ASHP runs, I don't believe there's any issue there, this was something the heat specialist checked (bled, check TRVs o...
Well I'm now currently stuck in a who's liable for installing the buffer tank for this install / myself querying is this 100% going to rectify the iss...
Not posted for a little while as been busy with other things. I've kept the system on Grant's default WC settings. It's been mostly quite mild so h...
I believe it’s all been balanced. Chap said they’re all filling up well once got air out system. Other half has moaned it’s now too warm so dropping...
Heat specialist came yesterday. Initial impression was downstairs rads seemed physically small. And by comparison felt upstairs was oversized. Ov...
Starting to see that even though downstairs calls for heat, when other zones don’t the ASHP turns off due to equal temp in and out. Soon as I upped un...
I'm going with: 2102 - 40C 2103 - 35C That's around 38C at 7C outside. This morning, combined with a bit too much of a drop for upstairs aft...
Oh definately. The house proportionally the said downstairs zone is also the largest, with 2 rooms equal to underfloor zone. I think the hall and land...
Changing the secondary pump to speed 1/3 seems to have had quite an impact. Downstairs can hit 21c consistently. However effectively almost running 24...
Yeah, I've set it back to 45C to see how it goes today/overnight. It's 3C outside. Downstairs zone is showing 20.2C. Probe in living room 19.4C. I...
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 215 Online
- 6,029 Members
Join Us!
Worth Watching
Latest Posts
-
A couple of days ago, I noticed that the pressure had d...
By ChandyKris , 1 hour ago
-
How long will your energy contract last?
Some heat pump tariffs don’t run as long as a heat pu...
By Toodles , 1 day ago
-
@morgan They are unsupervised these days, can’t get the...
By Toodles , 1 day ago
-
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@kevh it's worth remembering that many lsvs only actual...
By JamesPa , 2 days ago
-
RE: Setback savings - fact or fiction?
Exactly. We only need to compare conditions, to decide ...
By cathodeRay , 2 days ago
-
RE: Balancing financial efficiency and comfort using the Octopus Cosy tariff
I found because I have very low heat loss I can set bac...
By RadWhisperer , 2 days ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Welcome @mickamills We too have an oversized 12kW Sa...
By Old_Scientist , 3 days ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@caron I can confirm that the power usage of the PW3 is...
By Old_Scientist , 3 days ago
-
RE: Speedcomfort radiator fans
Thats true, but having tried (and succeeded) in constru...
By JamesPa , 3 days ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash brilliant, thanks for the feedback
By energy9165 , 3 days ago
-
RE: Heat Pump Heats the House… But It’s Not Cosy. Emitter Changes or System Tweak?
@alastair There I was, feeling grumpy, he said “Cheer u...
By Toodles , 3 days ago
-
RE: Grant Aerona: Is there a setting to keep the 2-port valve open during pump blockade
Depends on OAT. Mine cycles at OAT>10 and of course...
By JamesPa , 3 days ago
-
RE: New Fogstar 15.5kWh upright solution
@transparent My conclusion is as you have noted, tha...
By Bash , 3 days ago
-
RE: Mitsubishi Ecodan R290 10kW performance
And to you too. Wishing you a very enjoyable festive s...
By Sheriff Fatman , 3 days ago
-
RE: External pipework insulation
They do? But that isn't apparent from the photos we'r...
By Transparent , 3 days ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 4 days ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 4 days ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 4 days ago