Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 28, 2026
Plumber clarified his changes (he never mentioned he’d upped 2102 to 53.5C) ASHP pump speed changed to 1 At manifold - each loop set to 1 litre a ...
I’d forgot to change the leave temp to 21c downstairs. Heatmiser showed 19.8c first thing. That’s after 2 hours of 21.5c temp call for. House was ve...
Yeah, I'm hoping between the lagging and some balancing done today that won't keep happening. Removing 2 of the hot water cycles helped as well. Wi...
I had it at 22c on and 21c 'off'. So technically it just never reached 21C at all - the zone always calls for heat. I'd not seen 21c in the room its...
Thanks Mike, I'll give 3-4pm a go tomorrow to compare against today on our usage.
Yeah, I had actually changed 2102 from 50 to 45C for a few days and didn't notice any difference in the downstairs temp before (maybe .1-.2C temp when...
…and would also appear changed the ASHP settings, one I know: 2102 - is now 52.5C up from 50C So the WC would imply run at 48C at 7C outside. Qu...
And totally forgot to add, the 4th temp probe that sits in one of the living rooms is showing 21.2C atm. I can't recall seeing that at this time of d...
Plumbers returned. External lagging upgraded (removed valve handles to be screwed back on when needed so no gaps in lagging also). And plant room f...
Very much so. I’ve complained to architect who acts as design manager for project and certifies each months fees. Definately at point of wanting some ...
…so that turned out a valve was closed in plant room which was the rear bedrooms. The amount of errors is really getting to me. off the back of that...
Thanks @iancalderbank , you've guessed right, they've not since come and done a full balance.The room I work from was rather cold this morning, then r...
- 27 Forums
- 2,808 Topics
- 66.3 K Posts
- 1,146 Online
- 7,212 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@susannasaunders That's a serious amount of solar PV ...
By Rob of York , 4 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
So far there is nothing on the value of the BUS grants ...
By Rob of York , 7 hours ago
-
Coming back on subject... A shortened version of the ...
By Transparent , 10 hours ago
-
RE: Say hello and introduce yourself
Perhaps it is time for an update on ‘our’ project. We h...
By Toodles , 11 hours ago
-
RE: Marvel Heating liquidation
The interesting thing about the IBG: when I called them...
By davidnolan22 , 1 day ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
JamesPa The chart explains well how the heat curve an...
By trebor12345 , 1 day ago
-
RE: Free app: run the immersion / heat pump from Growatt battery & solar surplus – no Home Assistant
Please bear in mind, everyone, that in order to use thi...
By Majordennisbloodnok , 2 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis Thanks for posting this and Im so pleased you ...
By JamesPa , 2 days ago
-
RE: I need help with Ecodan ASHP
@f1p It turns out there have been a solar panel install...
By Andris , 3 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews your installer would be right to say that the...
By GrahamF , 3 days ago
-
RE: Tradespeople on Their Phones: What’s Acceptable When They’re Working in Your Home?
Actually, that's a very important point. I've only ev...
By Majordennisbloodnok , 3 days ago
-
RE: Aerotherm and weather compensation
These are likely inked. The basic explanation is tha...
By JamesPa , 3 days ago
-
RE: Electrical works for air to air heat pump
agree with above. I have not had extra costs added wh...
By Batpred , 4 days ago
-
Good to hear that you found a solution. Absolutely a...
By Batpred , 4 days ago