Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 28, 2023
I got the pipes on the hot water cylinder lagged (although ran out for a small area). Shocked at the difference it made. Heat loss went from 0.46 degr...
@iancalderbank @derek-m I got some thermometers onto the pipes to/from the buffer. At flow temp of 37 degrees from ASHP to buffer 36.7 from buffer...
Oh that's interesting. I was kinda hoping it'd be a lot more of a difference! But those numbers seem to be similar to what I'm seeing.
@iancalderbank McDonald Water Storage Vented 200L cylinder
@iancalderbank The pipes around the hot water cylinder have no insulation... so that's a job for this weekend. The pipes around the HP in the boiler r...
@iancalderbank thank you. I've purchased the thermometers and will go from there.
I stayed up til way past my bedtime to watch what the DHW does. Apparently drops at 0.46 degrees an hour, which seems quite high. So 11 degrees a day....
Does using the schedule override DHW heating the rest of the time? Or do you change the "temp to start heating" so low that it never heats, until the ...
I found the heat loss calcs. House size 230sqm. For space heating the house requires 26,479 kwh/yr. The HP is expected to consume 7,653kw/yr with a ...
I worked out the COP and usage/generation for the last few days. The weather turned on Jan 14 (from 10-12 degree high to 0-4 degree high), so perhaps ...
@william1066 thanks for sharing. All makes sense. Nice to know others are going through the same tinkering, though I'm jealous of your graph! How do y...
@craig1980 ha, are any of them?
- 26 Forums
- 2,675 Topics
- 62.6 K Posts
- 221 Online
- 7,090 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
@majordennisbloodnok I just noticed that A2A manufac...
By Batpred , 27 minutes ago
-
RE: Help me keep the faith with my air source heat pump installation
I didn't know about those, they look like good pieces o...
By JamesPa , 30 minutes ago
-
@mkz, that's very helpful. Even if Urban Plumber are no...
By Majordennisbloodnok , 37 minutes ago
-
RE: Several AC coupled batteries
That is a good point, a manufacturers can stop trading,...
By Batpred , 1 hour ago
-
My first question is why bother with the auto balancin...
By JamesPa , 2 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Hi @hanno - good question. The range of hybrid invert...
By Transparent , 2 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent the inverter was installed in 2021 and afa...
By Tim441 , 2 hours ago
-
I share the same experience as @majordennisbloodnok hav...
By Old_Scientist , 3 hours ago
-
RE: Say hello and introduce yourself
I hope so, @toodles. It's not often that we see a situa...
By Majordennisbloodnok , 6 hours ago
-
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump
@jamespa many thanks, definitely i will give the pre...
By ragtime27 , 17 hours ago
-
RE: Heat pump installation quotations
@jamespa I noticed that in the Heat Geek design consult...
By Batpred , 19 hours ago
-
RE: Electricity price predictions
Good point, I do expect the bonus of putting my energy ...
By Batpred , 1 day ago
-
RE: Daikin ESPAltherma and Home Assistant installation
@bash, something we haven't touched on already relates ...
By Majordennisbloodnok , 1 day ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Vaillant arotherm plus 12kW. Installed March 2025. Ex...
By Harebell , 2 days ago