Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Batpred
Batpred
@batpred
Member
Noble Member
Joined: Jan 3, 2025
Last seen: Sep 13, 2026
Topics: 12 / Replies: 1132
Reply
RE: Several AC coupled batteries

@ian33a I agree, even if it was not particularly unsafe. The main risk in my build was following outdated leaflets and damaging any electronics.

3 months ago
Reply
RE: Several AC coupled batteries

@etchedpixels Absolutely, I built mine as I assumed it was as simple as Fogstar made it look like. But even then, instructions were not fully up to da...

3 months ago
Reply
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump

For a sealed cylinder, the pressure is the same as mains, no matter where the cylinder is. And if too many taps are open, it will be the same no matte...

3 months ago
Reply
RE: Heat pump installation quotations

@jamespa I noticed that in the Heat Geek design consultation output - heat loss report. For ours (and almost all our rooms are airtight), half the the...

3 months ago
Reply
RE: Helium heat pumps

I would bet this does not hit the market before the current period of the gas boiler upgrade scheme, that is running until May 2027 offering £7.5k (if...

3 months ago
Reply
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump

@ragtime27 Our home is a bit different from the usual. We have a pressurized cold water cylinder with a in&out 22mm pipe. This means that, no m...

3 months ago
Reply
RE: Heat pump installation quotations

@sttpd1917 Thank you, the heat loss figures vary but not by too much. The costs are significantly higher than what we saw, but that is partially...

3 months ago
Reply
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump

Looks like a very detailed and well comprehensive heat loss calculation with all the related statements. In case your hot water pipework is over 15...

3 months ago
Reply
RE: Several AC coupled batteries

Sorry I missed this post. The introduction of a hybrid inverter with backup/ups capability has been discussed before in this forum, probably relevan...

3 months ago
Reply
RE: Several AC coupled batteries

You mean, no longer having the usual consultation period? 😉 I have no future crystal ball but would expect more of a compromise/deadlock si...

3 months ago
Reply
RE: Several AC coupled batteries

  Not exactly what you seem to be looking at, but a system like the below can work even when you want to maximise internal use rather than expo...

3 months ago
Reply
RE: Heat pump installation quotations

@sttpd1917 We did not find a mature heatpump market. We had to get many estimates and then proceed to narrow options via heat loss surveys for real ...

3 months ago