Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 3, 2025
@editor its the EIS or BEIS Schemes. Anyone with a small business, which meets the criteria can apply and get investors. The terms are very generous a...
I bought one off gumtree - I think it was around £45
I built a solution for sprinklers some years ago. Buy a used IBC, put it at the top of the garden and have a hose with a stop cock installed. Fill tha...
@transparent as an FYI I do have the old G59 as my panels are over 4kw and it's applied to my current Sofar ME3000SP
@transparent at these prices I might just buy two more Sofar units - it's basically the same price and just put each one with it's own battery!
@transparent interesting I'll take a look at them. Currently top of my running is a Goodwe unit. I also want the 100amp charging capability to maximis...
@cathoderay honestly, just bump up they power. If there is ever a problem you can just swap it back. However I doubt anyone would even check and if th...
@transparent I forgot to ask. What are you currently using to control the charging? I'm using a Sofar ME3000SP at the moment and it works really well....
@cathoderay if you really are struggling then it's time to investigate deeper. Step one, go flip the dip switches. No one would ever know and you'll g...
@cathoderay are you running on weather compensation? You might want to consider bumping the settings up and see how that affects things
@cathoderay if you had the loss calcs and the right sized ASHP, my question is, why isn't it making enough heat?
@cathoderay did you do your own heat loss to compare?
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 417 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 2 hours ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
Sooooo, what did we do in the end? We approached three ...
By Penval , 2 hours ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 7 hours ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 9 hours ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 9 hours ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 10 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 1 day ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 1 day ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 2 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 3 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 4 days ago



