Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 3, 2025
@editor I have to say, I don't really need to jump through hoops. My issue is that I think the data isn't quite detailed enough. Just a decimal point ...
@bramshot the defrost cycle is directly linked to the flow temperature your system is operating. The lower flow temperatures mean the pump will not ge...
@bramshot just put it down by two or three degrees. Leave it a couple of days to see how the house feels. If it's ok, then tweak a bit more. Organical...
@bramshot what I mean is that you have a flow temperature from the weather compensation. Cycling means it's heating up and then turning off, or defros...
@cathoderay could you emulate an Android phone on the PC and capture the data coming in. Maybe via wireshark?
@bramshot my rads are all normal double type rads. Honestly I'd give lower flow temps a go. The worst case is you turn it back up. Low and long is the...
@bramshot I've got rads. Honestly use some weather comp. You can go below 37° you'll be fine.
100% this heat pump is being used like a gas boiler. Turn down the flow temperatures and it'll stop icing up. It needs to be used in the heat pump swe...
Update from Midea Q to Midea: I was wondering if you were able to update the module for your heat pumps in the app? The reporting only shows in si...
@marzipan71 our installer kindly left the below on the heat pump controller. Needless to say we changed all the settings immediately and got far bette...
Here is a clear example for people on logging issues with apps. On the left you have the reported from my Midea app, 2kw per hour for the heat pump. O...
I use my COP figures as a broad brush and they do show what would be expected - lower flow temps and warmer days are more efficient. I am not sure wha...
- 26 Forums
- 2,647 Topics
- 61.8 K Posts
- 689 Online
- 7,045 Members
Join Us!
Latest Posts
-
Any readers with an interest in Solar Farm generation i...
By Toodles , 6 minutes ago
-
RE: Heat Pump Operation in Summer - Valliant 7kW
Yup! Summer in Spring. Wonder if Summer will last unt...
By Majordennisbloodnok , 29 minutes ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
I had a look at the manual for the pro and it mentions ...
By Batpred , 2 hours ago
-
RE: Solar Produced vs Home Consumed
It's worth adding that if you have a hot water tank and...
By JamesPa , 2 hours ago
-
RE: Heat Pump Overpromising – What Were You Actually Told Before You Bought?
@editor Sorry Mars, I didn’t see a notification about ...
By Toodles , 2 hours ago
-
RE: Hitachi Heat Pump being replaced with Vaillant
Yes to be configured as a volumiser. The pump is to be...
By trebor12345 , 3 hours ago
-
RE: Anyone concerned about GivEnergy?
So it seems subscription day has finally arrived for Gi...
By TechnoGeek , 4 hours ago
-
RE: How many people are happy with their ASHP and do you believe them?
I agree, and not. Energy prices are a largely politica...
By JamesPa , 6 hours ago
-
Yes, you will need to notify them even if the inverter ...
By Old_Scientist , 7 hours ago
-
RE: Heat Pump Manufacturers Recommending Buffer Tanks
@tony-stolz, I think @jamespa has already covered the h...
By Mars , 20 hours ago
-
@editor "The interesting bit is that many modern invert...
By Singlespeed , 1 day ago
-
RE: Ecodan & MelCloud scheduling
With the prospect of warmer weather this week, I brough...
By downfield , 1 day ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
I reached out to MCS directly last week on this and her...
By Mars , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
My heating developed a really severe case of noise and ...
By JamesPa , 2 days ago