Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 3, 2025
Said it on another thread, but worth checking if you have a low loss header and if that's causing losses from your system. It could easily be a culpri...
@derek-m no issues since I swapped it. So looks like it was a bad board. I'll see if I can fix it and I've got another BMS then!!
BMS now installed and the old one out. Process took about 30mins from start to end. The longest part being moving the Pylontechs on the top off and ba...
@korwraith BMS is here
@cheshirecat you can look to see if you have one - it'll be near the inlet somewhere. They work by providing separation between your house and the hea...
@cheshirecat do you have a low loss header? That might be contributing to your issue by returning warm water directly back to the heat pump.
@cathoderay there might be a small spike from defrost in the image below. I think since we changed the settings we've had a lot less than we did last ...
@cathoderay to be honest I'm not sure. There might be a power spike overnight, but we set the dishwasher on timer for early in the morning. I'll take ...
@cathoderay I think KWh out is actually quite easy. It knows the flow temps in and out and know the flow rate. 1kw heats 1m3 of water by 1 degree. ...
@cathoderay I actually suspect that Midea under reports its COP figures. My power use for the whole house is 1.6kw when the ASHP is ticking over - the...
@cathoderay you can reach them on this email - iot_support@midea.com
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,329 Online
- 7,157 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@editor Thanks Mars, I have been enjoying playing with ...
By kilgorexv , 1 hour ago
-
New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
I am feeling baffled and worried:We are having a an Aro...
By GutoFfowc , 4 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 7 hours ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 7 hours ago
-
RE: Questions about A2A for heating as well as cooling
@donciccio I would suggest that you take a "fabric-fi...
By Rob of York , 8 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 1 day ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 2 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 3 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 6 days ago