Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

afarmery
@afarmery
Member
Active Member
Joined: Dec 8, 2023
Last seen: Apr 28, 2024
Topics: 2 / Replies: 11
Reply
RE: Question about Ecodan's Room Autoadapt mode

@gary Thanks. I'm emboldened to give it a go!

2 years ago
Reply
RE: Question about Ecodan's Room Autoadapt mode

Derek et al, Sorry for resurrecting this slightly old thread, but I'm now back at the property in question after a time away. When I attempt to acce...

2 years ago
Reply
RE: Question about Ecodan's Room Autoadapt mode

Thanks HarriUp. The COP figure of 6 was calculated from Energy out/Energy in, as displayed of the FTC6, but I'm not sure how accurate that is. Ma...

2 years ago
Reply
RE: Question about Ecodan's Room Autoadapt mode

Thanks. Not sure about mixing valves. But when I ran my system on the manually set curve, I had it at 32C when outside temp was 0, and 21C was outsid...

2 years ago
Reply
RE: Question about Ecodan's Room Autoadapt mode

@ajdunlop Thanks for this. I'll give it a try. At around the same location in the menu there's the option to alter the min and max flow temperature ...

2 years ago
Reply
RE: Question about Ecodan's Room Autoadapt mode

@derek-m Thanks Derek, I managed to download a manual where it states that the 'interval' default is 10 minutes, but can be increased to a max of 6...

2 years ago
Reply
RE: Question about Ecodan's Room Autoadapt mode

@derek-m Thanks. If you're able to point me to where I can do this in the app, I'd be grateful. A.

2 years ago
Reply
RE: Question about Ecodan's Room Autoadapt mode

Thanks Gary for that succinct reply to my rambling question. I'll try it for a bit and see how it goes. It's a shame their isn't an option for eithe...

2 years ago
Reply
RE: How to program setback (Ecodan 5.0)

@editor I didn't resolve the issue really. My system is an Ecodan 5kW. I understand that it might be possible using Melcloud (but I'd need to buy an...

2 years ago
Reply
RE: How to program setback (Ecodan 5.0)

@abernyte Thanks. The installer fitted 3rd party stats (Heatmiser) and 'lost' the Ecodan WiFi interface, so looks like I'll have to purchase both the...

2 years ago