Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Oct 21, 2026
Topics: 16 / Replies: 3418
Reply
RE: Preparing for 2nd winter in new build house.

Yuch! So that's basically just an on/off control. It either lets water flow through a loop at anything up to 60°C, or it doesn't.   The t...

1 year ago
Reply
RE: Preparing for 2nd winter in new build house.

Where are those thermostats? On the UFH manifolds? Photo?   The photo you've just posted of the pipe before screed is poured: Is that a...

1 year ago
Reply
RE: Preparing for 2nd winter in new build house.

Ah. That sounds better. So that just leaves the heat-pumps in a battle whereby OAT-based weather compensation is being thwarted by thermostats turni...

1 year ago
Reply
RE: Preparing for 2nd winter in new build house.

Oh good grief! The Outside Air Temperature (OAT) is the main mechanism by which a heat-pump regulates the flow speed & temperature.Setting Weath...

1 year ago
Reply
RE: Preparing for 2nd winter in new build house.

OK, so that explains the 3ph issue a bit more.You're on the sliver of West Sussex for which UK Power Networks is the DNO 😥 UKPN is Chinese...

1 year ago
Reply
RE: Preparing for 2nd winter in new build house.

The electricity supply: I too am very surprised at this. I don't understand why the DNO didn't insist on this being a 3ph supply! The thresho...

1 year ago
Reply
RE: Say hello and introduce yourself

Please tell us more @sbm74 How many m² do you have such that more than one heat-pump has been installed? Are they working independently?Or do they...

1 year ago
Reply
RE: Big Changes Coming to Our Heat Pump System

1: Because, deep inside, they realise that the MCS guidance has got them installing HP's which are actually over-sized.The buffer tank throws away hea...

1 year ago
Reply
RE: Big Changes Coming to Our Heat Pump System

There's a couple of motorised valves I can see there.Put them on ebay, and you'll be able to cover the cost of Brendon's coffee for the duration. Ho...

1 year ago
Reply
RE: Is Your Broadband Router the Weak Link in Your High-Tech Home?

If the 'cellular technology' is actually the GSM system (and we can't be certain of that),then there's no need to access the backbone. A malicious a...

1 year ago
Forum
Reply
RE: Is Your Broadband Router the Weak Link in Your High-Tech Home?

@scalextrix You're assuming that the source of the command is to be China.It could just as easily be someone sitting in a field a couple of miles away...

1 year ago
Forum
Reply
RE: Is Your Broadband Router the Weak Link in Your High-Tech Home?

True, But the GB grid itself is likely to be compromised already. See this press release from Reuters on 15th May '25, which was written into stor...

1 year ago
Forum
Page 80 / 287
Share:

SPONSORS

Join Us!

Installer Finder

Degrees of Separation

Latest Posts

SPONSORS

Click to access the login or register cheese
Protected By
Shield Security PRO