Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Sep 11, 2026
Topics: 16 / Replies: 3375
Reply
RE: Smart meter installation – seamless or a potential nightmare?

To derive a gas bill in kWh from the meter readings in m³ (cubic metres) x 1.02264 (volumetric correction - a constant, based on barometric pressur...

2 years ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

Yes. The only route to communicate commands to a Smart Meter and receive data from its registers is via DCC.All communications paths in/out of DCC are...

2 years ago
Reply
RE: Jokes and fun posts about heat pumps and renewables

I think that's Miliband, rather than Milligan @editor 😊 And for those who don't know, he's Shadow Minister for Energy Security & Net Z...

2 years ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

Why would a sensor for external air temperature be placed in the airflow being drawn through the fins? Placing it within a sleeve might provide mech...

2 years ago
Reply
RE: Battle of the charging technologies

I think we need to consider the charging schedule against a wider range of inputs than those commonly used within HA. The present EV Charging legisl...

2 years ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

I can't find that exclusion clause in the Consumer Rights Act! That's only 5 months ago, anyway.That doesn't sound an abnormally long interval befor...

2 years ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

The 'banding' can be read as a bar-code which describes how well the defrost cycle is operating 🤔 Was the cavity insulation work ...

2 years ago
Reply
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?

Oh dear, oh dear!Let's take this one point at a time. 1: Are you saying that they drilled 22mm holes vertically through the (suspended) concrete...

2 years ago
Reply
RE: Smart meter installation – seamless or a potential nightmare?

There are a great many layers in the questions you're posing here, Ian.Allow me to first give some clarifications.We can then better understand the is...

2 years ago
Reply
RE: Say hello and introduce yourself

You might wish to see what I wrote this morning about 'handover' on a topic about Bad Installation instigated by another new member of this forum. A...

2 years ago
Reply
RE: Is this a bad installation? Is there something wrong with my heat pump?

No, not good, @david999 😣 Your heat pump works by keeping a 5°C differential between the Leaving Water Temperature (LWT) and the Return Wat...

2 years ago
Reply
RE: Is this a bad installation? Is there something wrong with my heat pump?

Whilst everyone else is discussing the ice, may I comment on the pipework? The standard of the insulation and the way it is routed through the wall ...