Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Aug 4, 2026
Topics: 16 / Replies: 3332
Reply
RE: Delivering a smart and secure electricity system: government consultation

I'm in the loop because I'm a Member of the SEC 🙂 Who is 'we' in the phrase "but we missed that one"?Do you work in the energy sector or a ...

2 years ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

Thanks for that link @ianmk13 - and that Notice conflicts with explanations given to me by local network engineers.However, it is issued by Seth Treas...

2 years ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

Do you have an evidence of that practice? It isn't NGED's policy in the four regions for which they hold a Distribution Licence.That includes the re...

2 years ago
Reply
RE: EV charger installation question – I don't want to bury the cable

It's not 'crossing' a path or garden except for one point near the back door. The intended cable-run is mainly along a fence...which we don't yet kn...

2 years ago
Reply
RE: EV charger installation question – I don't want to bury the cable

Thanks @hem That looks like a SMETS1 meter with an Elster (Honeywell) Communications Hub operating at 900/1800MHz for connection to the National ...

2 years ago
Reply
RE: EV charger installation question – I don't want to bury the cable

Just a reminder @hem - we do need to know whether your house has its own earth stake, or if earth is provided via the 100A service fuse. You shoul...

2 years ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

Delivering a Smart and Secure Electricity System is an ongoing program rather than a one-off consultation. There was an earlier consultation round h...

2 years ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

@eggnchips your location is still likely to attain access to the UK Smart Meter Network. DESNZ opened a consultation on proposals to deliver access ...

2 years ago
Reply
RE: EV charger installation question – I don't want to bury the cable

@hem that's a good observation from @ianmk13 Here's a link to that SWA with integral CAT5e data cable, also from TLC Direct.Note that they sell it p...

2 years ago
Reply
RE: Say hello and introduce yourself

If you're facing possible nighttime temperatures down to -6°C then you'd avoid pipes freezing with just 15% glycol. I use a 20% solution in the pipe...

2 years ago
Reply
RE: Say hello and introduce yourself

Thanks for those insights @eggnchips For others who come across this in future, let me point out that the higher the concentration of glycol, the lo...

2 years ago
Reply
RE: EV charger installation question – I don't want to bury the cable

I can't remember where either 😖 Can I check if you are intending to use a recognised EV Charger installer in order to take advantage of a ...

2 years ago
Page 169 / 280
Share:

SPONSORS

Join Us!

Installer Finder

Degrees of Separation

Latest Posts

SPONSORS

Click to access the login or register cheese
Protected By