Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Sep 10, 2026
Topics: 16 / Replies: 3374
Reply
RE: Battery sizing - How low can you go!

The SunSynk 5kW unit gives you more kW per £ than the 3.6kW you linked to. I was suggesting a DIY wind-turbine rather than off-the-shelf.If you have...

2 years ago
Reply
RE: Battery sizing - How low can you go!

No. You need two inverters to incorporate the 2.66kW array.Each inverter will have two MPPT inputs. That still gives you one 'spare' input for renew...

2 years ago
Reply
RE: Battery sizing - How low can you go!

Ah yes. I'd forgotten the East/West split.So you will require two MPPT inputs for that arrangement. The Huawei Luna 2000 has a particularly low mini...

2 years ago
Reply
RE: In the middle of an ASHP installation - a few questions (and issues)

Yes.... hence my comments about theft-prevention on p.1 of this topic! Having longer hose connections also makes it slightly easier to maneuver a tr...

2 years ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

Now we're in the realm of circulatory systems and buffer tanks, I need to pass the baton to those who better understand the principles. Have a look ...

2 years ago
Reply
RE: Battery sizing - How low can you go!

Ah... someone with experience of radiography ! So if I help you with putting together a suitable battery storage solution,could you advise me on the...

2 years ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

Post Trusses. Great... so these trusses are very strong and transfer weight to the main load-bearing walls. One possibility is to suspend a platfo...

2 years ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

Then note that this Topic forms part of your evidence! Please forward the URL to whichever 'bodies' you get to communicate with,ideally highlight sp...

2 years ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

Thank goodness for that! So they are at least a wee bit concerned at a Health & Safety risk! Whatever they propose to support the weight of th...

2 years ago
Reply
RE: New Fogstar 15.5kWh upright solution

That reply from Fogstar is in response to a question about a battery rated at 13.2v,which tells me that it's probably four LiFePO4 cells in series. ...

2 years ago
Reply
RE: New Fogstar 15.5kWh upright solution

Hi @littlefinger and well done for finding an appropriate topic in which to post 🙂 Firstly, the Fogstar storage batteries have no direct co...

2 years ago
Reply
RE: Battery sizing - How low can you go!

There are no post-installation checks on installations which have already been accepted for FIT payments.For example, if your Fronius inverter were to...