Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Sep 10, 2026
Topics: 16 / Replies: 3373
Reply
RE: Adding underfloor heating to existing HP system

What type of floor structure will this be? I have successfully undertaken "pipe in concrete pad" and pipe with heat-spreader plates between ...

2 years ago
Reply
RE: Getting the best out of a heat pump - is Homely a possible answer?

Yes, I appreciate that example. The 'problem' here is that Homely is making a decision based on price rather than: energy efficiency of the heat...

2 years ago
Reply
RE: Midea 16kW R290 ASHP with plans for battery, PV and monitoring

That's an expensive way of buying battery storage @amuseboucheukHave a look at this discussion on A Business Case for Buying a Battery. The inverter...

2 years ago
Reply
RE: Midea 16kW R290 ASHP with plans for battery, PV and monitoring

Here's the electrical specification from the installation manual for the Midea 16kW ASHP So this is 3-phase (?).The instructions stipulate it shou...

2 years ago
Reply
RE: Getting the best out of a heat pump - is Homely a possible answer?

A heat pump should be always running. The initial survey is to calculate the heat loss for the entire house. That provides the power output requir...

2 years ago
Reply
RE: Getting the best out of a heat pump - is Homely a possible answer?

I agree with @cathoderay @starkers you really do need to get rid of that on/off cycling.That's not how a heat pump is meant to operate. The Outsid...

2 years ago
Reply
RE: Getting the best out of a heat pump - is Homely a possible answer?

Meanwhile, Transparent has been busy installing cables below floor level...... and topics going off-piste weren't featuring highly in the mind. ...

2 years ago
Reply
RE: Difficult positioning of air source heat pump

Let me add two further thoughts into the mix @rikiarn 1: An ASHP doesn't have to be at ground level.There are wall-mounting kits available,and s...

2 years ago
Reply
RE: Samsung E911 intermittent issue

If removing that strainer made a difference, then it's possible that something has become dislodged within the pipework. We can't tell if that 'some...

2 years ago
Reply
RE: Samsung E911 intermittent issue

OK, so things are heading in the right direction.There may still be some air in the pipes which has yet to come out. Or you could now be approaching...

2 years ago
Reply
RE: Samsung E911 intermittent issue

Opening that strainer, will of course lose fluid from the system and introduce air. You don't have isolation valves on either side of it which would...

2 years ago
Reply
RE: Samsung E911 intermittent issue

Yes. It's usually called a strainer. It's also uninsulated,...and the adjacent pipe insulation isn't sealed. This will allow ingress of rain water...