Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 20, 2026
Good day all. Questions on heating using fan coils: 1. can one use weather compensation with fan coils ? 2. Do fan coils require higher water ...
@grantmethestrength OK, thanks, I don't use HA, I have written my own interface in MATLAB, if you know.
@grantmethestrength What are "blueprints" please ?
@cathoderay what is the setting for room thermostat ? (bottom lines of 1st page of instructions)
@cathoderay well exactly because it says so on the screen. Furthermore, the fact that curve 9 is shown as selected does not mean it is in effect. I ag...
@cathoderay I am pretty sure your unit is set to operate on "Water temperature control" and not on WCC control.
@cathoderay Are you using Midea's wired controller to operate the heat pump or some other method (modbus or whatever). Furthermore, even with a fixe...
@cathoderay I tend to agree with Mk4. Why don't you try his suggestions and see what happens.
In my controller, this can be done in service menu: Also noted:
@cathoderay I think the 45 C is the set LWT if you operate on LWT control, not the LWT calculated from the WCC. Further, IAT set-point, defined at t...
I confirm system shutting down after exiting the SERVICEMAN MODE but not shutting down when parameters changed through direct modbus communication. ...
I have not noticed something of that sort but I will check tomorrow to be sure.
- 26 Forums
- 2,676 Topics
- 62.6 K Posts
- 252 Online
- 7,090 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Harvest Thermal - ASHP with a smart thermal battery
As its using ToU tarrifs then its totally believable so...
By JamesPa , 1 hour ago
-
Why do you want to maintain a specific deltaT? The out...
By JamesPa , 1 hour ago
-
RE: Heat pump installation quotations
@batpred Excellent, thank you very much!
By sttpd1917 , 2 hours ago
-
Hopefully this will answer your question. To...
By ASHP-BOBBA , 2 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
I would be interested to find out if others do this and...
By ASHP-BOBBA , 2 hours ago
-
Don't you dare. You just carry on as you are; as @batpr...
By Majordennisbloodnok , 4 hours ago
-
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump
@ragtime27 some rooms in our house only have one place ...
By Judith , 4 hours ago
-
@mkz, that's very helpful. Even if Urban Plumber are no...
By Majordennisbloodnok , 7 hours ago
-
RE: Several AC coupled batteries
That is a good point, a manufacturers can stop trading,...
By Batpred , 8 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Hi @hanno - good question. The range of hybrid invert...
By Transparent , 8 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent the inverter was installed in 2021 and afa...
By Tim441 , 9 hours ago
-
RE: Say hello and introduce yourself
I hope so, @toodles. It's not often that we see a situa...
By Majordennisbloodnok , 12 hours ago
-
RE: Electricity price predictions
Good point, I do expect the bonus of putting my energy ...
By Batpred , 1 day ago
-
RE: Daikin ESPAltherma and Home Assistant installation
@bash, something we haven't touched on already relates ...
By Majordennisbloodnok , 1 day ago