Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

SUNandAIR
SUNandAIR
@sunandair
Member
Honorable Member
Joined: Dec 30, 2022
Last seen: Mar 21, 2026
Topics: 5 / Replies: 564
Reply
RE: Ecodan Room Temperature Mode

How are people using the Mitsubishi wireless remote. I’ve only used it with Auto Adaptive / room temperature mode. As a target room temperature contro...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

indeed this is part of the conundrum But I think Auto Adapt, and it’s tendency to overshoot then cool back is also part of the same problem. You may r...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

@derek-m hi Derek, The points you raise are all very valid and ones we’ve been becoming familiar with. We are all too familiar with understand...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

I don’t think your first assumption is having an effect on the end of the day. But I can confirm your second point. The radiators were fully heated at...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

Answers to the quiz: Low flow rate vs high flow rate. The 11 o’clock graph is operating at 19lpm and the 12 o’clock and 15 o’clock graphs were opera...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

Thats interesting… I haven’t seen such super high temps. I’ve never thought of containing the upper temperature limit. I have mine set to 53c because ...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

hi @gotaashp I was interested in your 24 hour room temp graph which shows how AUTO ADAPT tries to anticipate and over run set temperatures. Its i...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

Hi Walker, Thanks for your thoughts. The good news about the rating of Ecodan is that the output range of the compressor is quite a bit higher than...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

Here is a challenge for you Derek: One of these graphs is recorded during a flow rate of 19lpm and 2 of the graphs are recorded at a flow rate of 14...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

Thanks that sounds interesting Kev Meanwhile, I’ve changed to WC curve it is set at 31c at today’s outside temperature of 8c. So I’ve added +2 to b...

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

hi, I’m pretty sure it’s no coincidence. Earlier in the month I was getting 20 minutes cycling but, like you, I also had the period set to 20 minutes....

3 years ago
Reply
RE: Ecodan Long Cycling and AA behaviour in one day.

Operating in AA. We have been getting reasonable ‘on’ time yesterday since we extended the ‘Room Temp. control’ interval. This is the interval period ...