@dgclimatecontrol Thanks... this was resolved back in March/April.
@davidnolan22 Hi..! We've only just turned on the heating again following the summer but it's not overly concerning right now. It's cycling a little b...
@gary The tank is 210 litres. I work from home as a baker so I can use a lot of water during the day but using the old MegaFlo and oil boiler, we neve...
Thanks James, this is still something on the to-do list. I know there's more diagnostics to be done. I was just hoping the new pump would stabilise th...
Thanks. I still need to check this out. It's taken all my mental capacity to wrap my head around the heat pump. So it should be as simple as just adju...
I haven’t looked at that side yet. But so far, the only thing that’s changed is that we’ve had the heat pump changed and COP is getting worse. I can s...
@jamespa It does appear to be going into defrost more frequently than the previous pump at similar temperatures. Would that account for the higher ene...
@jamespa Thankfully they didn’t touch the settings. They checked the pressure on the tank but that’s all.The only work they did was on the external un...
Just a follow up… first full day of the new heat pump… worst COP in weeks. COP down from a regular 3.4 to 3.8 to 2.7 yesterday (that’s just heating, n...
Just a bit of an update... thanks to the information you've shared with me, I was able to argue the case of the oversizing a little better.They revisi...
@jamespa Thanks James. The DHW COP is the worst we've had yet strangely. And there were no big drains on the water yesterday. It's like it's heating...
@jamespa Thanks for this.The COP for yesterday was 3.57 (heating 3.79 water 0.87) so the DHW eco setting might be making a difference but I'll keep mo...
- 26 Forums
- 2,255 Topics
- 50.3 K Posts
- 404 Online
- 5,918 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Who has a V2G EV installation
The EV wall chargers implement the checking for dno lim...
By Batpred , 5 hours ago
-
RE: When will fusion be producing energy?
I am thinking of the case where AI was able to distingu...
By Batpred , 5 hours ago
-
RE: What valves to replace radbots?
Before answering the question definitively, its necessa...
By JamesPa , 7 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@agentgeorge Where there’s muck … 😉 Toodles.
By Toodles , 9 hours ago
-
RE: Flexi-Orb Heat Pump Scheme: A Game-Changer for the UK's Heat Pump Industry
@majordennisbloodnok Thanks for the welcome and yes I...
By Mark Nelson , 11 hours ago
-
So after playing about with DHW settings for a while I ...
By bontwoody , 12 hours ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
I’ve got 5.4kW array, 9.6kWh battery, 5kW heat pump, EV...
By Gruff2001 , 15 hours ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
Very definitely. I think the market has changed a bit...
By JamesPa , 16 hours ago
-
RE: Buying large amp bidirectional RCD and RCBO
The following diagram is taken from the Meter Operator'...
By Transparent , 17 hours ago
-
RE: British Gas Heat Pump Installation Complaint
@steelbadger That's great to know! Thanks for that reas...
By BGNO , 21 hours ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@allyfish It was going so well with month after month s...
By Toodles , 1 day ago
-
RE: Electricity price predictions
As that's an energy issue, it would need the DESNZ to p...
By Transparent , 1 day ago
-
RE: UFH downstairs and radiators upstairs balancing question
Have you tried turning up the stat and turning down the...
By JamesPa , 1 day ago
-
-
RE: Mediation with RECC, what's your experience?
Welcome to the forums @treewizard and sorry to hear abo...
By Mars , 2 days ago
-
RE: New build installation query
That accounts for why you start with an overly-high DHW...
By Transparent , 2 days ago
-
RE: Daikin Altherma 3 / HomeAssistant
I would have thought that (instantaneous) power is a fa...
By JamesPa , 2 days ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
Alright, I concede that the Toyotas are, as you say a v...
By JamesPa , 2 days ago
-
RE: Is it mad to think there should be a minimum SCOP for UK heat pump installs?
Sadly I think it is mad. If the BUS is not granted for ...
By Judith , 2 days ago