Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

RobS
@robs
Member
Estimable Member
Joined: Oct 15, 2024
Last seen: Nov 25, 2026
Topics: 0 / Replies: 139
Reply
RE: Heat Pump + Dynamic / Smart Tariffs - what is your approach?

Presumably the timer for timed DHW, that @jaket suggested, is just the standard feature of an Ecodan controller (and other heat pump controllers), so ...

2 years ago
Reply
RE: Solar for heating DHW

That's odd, you should be able to set 3 or 4 levels of quiet in the installer menu. Mitsubishis also have an Eco mode for DHW, you might want to tr...

2 years ago
Reply
RE: Solar for heating DHW

@davidalgarve Much bigger heat pump than us but still a surprising amount of power, do you have it in Eco mode? Or use quiet mode? If it uses 3kW ...

2 years ago
Reply
RE: Solar for heating DHW

Most batteries are what is known as DC-coupled, which means that they use the solar inverter to convert their DC voltage to AC used in your house. So ...

2 years ago
Reply
RE: Ecodan with FTC7 controller DHW schedule

Cosy has the 3 hours of peak rate and the day rate is appropriately 1.5p per hour more - which is appropriately equivalent to another hour and a half ...

2 years ago
Reply
RE: Ecodan with FTC7 controller DHW schedule

142L is not very big but if you don't use much DHW then it's worth seeing if only one DHW reheat a day works. Do you have a battery with your solar...

2 years ago
Reply
RE: Ecodan with FTC7 controller DHW schedule

We also have a FTC7 and a newer R290 Mitsubishi heat pump. There are prohibits for heating and DHW, to schedule the DHW you want to prohibit the DHW f...

2 years ago
Reply
RE: Mixing of pipework/components' with different internal dimensions - theory vs reality/practical approach

I would suggest: Mag filter last on return so it filters out stuff before it gets to the outside unit. Do you also have a strainer in you system? ...

2 years ago
Reply
RE: The Definitive Guide to Weather Compensation and Curves for Air Source Heat Pumps

I don't know if the FTC6 and FTC7 are different in this respect but the FTC7 rounds up and down as you would expect (no odd .38 and .53 rounding point...

2 years ago
Reply
RE: From Auto adapt to W/C Ecodan

@westkent Almost, the wireless controller just becomes a limiter, if the internal temperature goes 1C above the set temperature then the heat pump w...

2 years ago
Reply
RE: From Auto adapt to W/C Ecodan

When on WC the WC curve controls the heating based on the outside temperature. You can use schedules for DHW (hot water) though. What are you trying t...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

A few Mitsubishi figures from their data book for comparison... 5kW output at 12C OAT: 5kW unit is COP of 6.15 11.2kW unit is COP of 5.9 ...

2 years ago