Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 25, 2026
142L is not very big but if you don't use much DHW then it's worth seeing if only one DHW reheat a day works. Do you have a battery with your solar...
We also have a FTC7 and a newer R290 Mitsubishi heat pump. There are prohibits for heating and DHW, to schedule the DHW you want to prohibit the DHW f...
I would suggest: Mag filter last on return so it filters out stuff before it gets to the outside unit. Do you also have a strainer in you system? ...
I don't know if the FTC6 and FTC7 are different in this respect but the FTC7 rounds up and down as you would expect (no odd .38 and .53 rounding point...
@westkent Almost, the wireless controller just becomes a limiter, if the internal temperature goes 1C above the set temperature then the heat pump w...
When on WC the WC curve controls the heating based on the outside temperature. You can use schedules for DHW (hot water) though. What are you trying t...
A few Mitsubishi figures from their data book for comparison... 5kW output at 12C OAT: 5kW unit is COP of 6.15 11.2kW unit is COP of 5.9 ...
To quantify the greater pressure drop of your corrugated pipe you could try using an online calculator like For example, at 20 l/min a 25.4mm corrug...
Yes, your figures correlate well with your heat pump having a minimum output of about 3kW at these outside temperatures. Have you tried your heat pump...
You have clearly found your system's sweet spot! Yes, radiator based systems are likely to be limited in stable low flow temperatures. But larg...
I'm pretty sure it just means output, using the word capacity in this way isn't unusual in Japanese documents (and if something has a capacity then it...
As far as I know yes.
- 26 Forums
- 2,647 Topics
- 61.8 K Posts
- 201 Online
- 7,045 Members
Join Us!
Latest Posts
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
@jamespa the answer to your question is in our A2A podc...
By Mars , 12 minutes ago
-
RE: Anyone concerned about GivEnergy?
The above is a screenshot of GivEnergy Software's lates...
By txmartyn , 26 minutes ago
-
@colinc Knock-Knock…. err, excuse me Colin C but I beli...
By Toodles , 37 minutes ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
Interesting. Perhaps wait and see how things develop! ...
By JamesPa , 3 hours ago
-
RE: Heat Pump Operation in Summer - Valliant 7kW
Yup! Summer in Spring. Wonder if Summer will last unt...
By Majordennisbloodnok , 4 hours ago
-
RE: Solar Produced vs Home Consumed
It's worth adding that if you have a hot water tank and...
By JamesPa , 5 hours ago
-
RE: Heat Pump Overpromising – What Were You Actually Told Before You Bought?
@editor Sorry Mars, I didn’t see a notification about ...
By Toodles , 6 hours ago
-
RE: Hitachi Heat Pump being replaced with Vaillant
Yes to be configured as a volumiser. The pump is to be...
By trebor12345 , 6 hours ago
-
RE: How many people are happy with their ASHP and do you believe them?
I agree, and not. Energy prices are a largely politica...
By JamesPa , 10 hours ago
-
Yes, you will need to notify them even if the inverter ...
By Old_Scientist , 10 hours ago
-
RE: Heat Pump Manufacturers Recommending Buffer Tanks
@tony-stolz, I think @jamespa has already covered the h...
By Mars , 23 hours ago
-
@editor "The interesting bit is that many modern invert...
By Singlespeed , 1 day ago
-
RE: Ecodan & MelCloud scheduling
With the prospect of warmer weather this week, I brough...
By downfield , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
My heating developed a really severe case of noise and ...
By JamesPa , 2 days ago