Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 10, 2026
@jancold Not a plumber but I believe that is the blending valve and pressure regulator. No experience on how to adjust it. Another thoug...
Have you considered the Thermostatic Mixing (Blending) Valve (aka Anti-Scald or Tempering Valve) that mixes the hot water with mains to control the te...
This is how Daikin run their heat pumps. Weather Compensation + Thermostatic control = Water pump runs Continuous or OnDemand (default) - configurab...
Enable installer mode - 5678 Enter the Space Heating/Cooling menu Enter Pump Operation Mode - Select Continuous or Sample (default) Enter Pump ...
I think it's worth adding here that when you enable the Daikin LWT mode the pump switches from demand/request to sample. That means the pump will cycl...
More like Octopus wanted to fit a Cosy 6 at the end of the garden, avoid planning permission and re-use the tiny airing cupboard. My preference was to...
@toodles Useful reply and because Heat Geek mentioned it in the Daikin MMI vid I didn't do any further checking. Using Grok again to sift through all ...
Just to say I did read this post before joining the forum and it inspired me to start looking up the LWT mode. I had seen the Heat Geek Daikin MMI vid...
Octopus - Daikin Altherma 3M 4KW heat pump install - April 2025 My overall experience has been excellent. My house is a fairly straight forward 2 be...
DAIKIN ONECTA Simple answer is not a great deal. You can monitor the current hot water and heating modes. The temps and targets are indicated when...
Daikin Altherma 3M - 4kW (R32 2022 Release) (EDLA04E2V3) Installed by Octopus April 2025.
- 26 Forums
- 2,646 Topics
- 61.8 K Posts
- 887 Online
- 7,045 Members
Join Us!
Latest Posts
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
I had a look at the manual for the pro and it mentions ...
By Batpred , 12 minutes ago
-
RE: Solar Produced vs Home Consumed
It's worth adding that if you have a hot water tank and...
By JamesPa , 30 minutes ago
-
RE: Heat Pump Overpromising – What Were You Actually Told Before You Bought?
@editor Sorry Mars, I didn’t see a notification about ...
By Toodles , 49 minutes ago
-
RE: Hitachi Heat Pump being replaced with Vaillant
Yes to be configured as a volumiser. The pump is to be...
By trebor12345 , 1 hour ago
-
RE: Anyone concerned about GivEnergy?
So it seems subscription day has finally arrived for Gi...
By TechnoGeek , 3 hours ago
-
RE: How many people are happy with their ASHP and do you believe them?
I agree, and not. Energy prices are a largely politica...
By JamesPa , 5 hours ago
-
Yes, you will need to notify them even if the inverter ...
By Old_Scientist , 5 hours ago
-
RE: Heat Pump Manufacturers Recommending Buffer Tanks
@tony-stolz, I think @jamespa has already covered the h...
By Mars , 18 hours ago
-
RE: Heat Pump Operation in Summer - Valliant 7kW
I do the same: cool my large buffer (3000L) to 10C, pum...
By upnorthandpersonal , 1 day ago
-
@editor "The interesting bit is that many modern invert...
By Singlespeed , 1 day ago
-
RE: Ecodan & MelCloud scheduling
With the prospect of warmer weather this week, I brough...
By downfield , 1 day ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
I reached out to MCS directly last week on this and her...
By Mars , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
My heating developed a really severe case of noise and ...
By JamesPa , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@l2jad I was just thinking all things being equal. Our ...
By AndrewJ , 2 days ago