Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 24, 2023
@kev-m Yes, I am not unhappy with that usage. Will have to see how it goes over the next few months, but it looks as though it's working out cheap...
@george @kev-m @rv3 I now have a full month of figures to work with, and I don't think my energy consumption is quite as bad as it seems from the Me...
@batalto Thanks for the suggestion - I'll give it a go.
@derek-m Hi Derek, TRV's are closed in my wife and I's bedroom because we like a cooler room to sleep in. TRV's are fully open on the first floo...
You haven't met my wife - that would not be a popular suggestion 🤣
Yes, that is true, and when I think rationally the numbers are less scary - I just need to get into the mindset that they represent our entire energy ...
@derek-m Hi Derek, Our installer has promised me a call back from someone in their technical team within the next 24 hours. Given their previous ...
@derek-m Hi Derek, Energy used and produced readings were taken from the FTC controller. No, I'm afraid we don't have any heat loss calculation...
@jeff Meter readings are from a smart meter. Nothing available online, because the meter hasn't been able to connect to the metering network since...
@derek-m Hi Derek, This is a quick sketch of our system that I knocked up this morning, not sure if it gives you all that you need: Also, her...
@derek-m Thanks for the advice Derek. I would like to leave the system in weather compensation mode for a day or so longer, so I can get realistic...
- 26 Forums
- 2,677 Topics
- 62.6 K Posts
- 194 Online
- 7,090 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Heat pump installation quotations
That will be absolutely murdering your energy efficienc...
By EtchedPixels , 58 minutes ago
-
RE: Harvest Thermal - ASHP with a smart thermal battery
The cooling side works much better if you can figure ou...
By EtchedPixels , 1 hour ago
-
Floor standing brackets for K3 rads
My neighbour is a plumber and said I would need to fit ...
By Singlespeed , 2 hours ago
-
After an intense recode, I’m pleased to announce that w...
By Mars , 2 hours ago
-
Why do you want to maintain a specific deltaT? The out...
By JamesPa , 3 hours ago
-
Hopefully this will answer your question. To...
By ASHP-BOBBA , 4 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
I would be interested to find out if others do this and...
By ASHP-BOBBA , 4 hours ago
-
Don't you dare. You just carry on as you are; as @batpr...
By Majordennisbloodnok , 6 hours ago
-
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump
@ragtime27 some rooms in our house only have one place ...
By Judith , 6 hours ago
-
RE: Several AC coupled batteries
That is a good point, a manufacturers can stop trading,...
By Batpred , 10 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Hi @hanno - good question. The range of hybrid invert...
By Transparent , 10 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent the inverter was installed in 2021 and afa...
By Tim441 , 11 hours ago
-
RE: Say hello and introduce yourself
I hope so, @toodles. It's not often that we see a situa...
By Majordennisbloodnok , 14 hours ago
-
RE: Electricity price predictions
Good point, I do expect the bonus of putting my energy ...