Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 13, 2023
Two weeks have passed since everything was commissioned. The ASHP has used 520 kWh of electricity so far, averaging 35 kWh per day (excluding the fir...
I've had my LG Therma V running for a week now. We have underfloor heating throughout. DHW is set to 50 degrees and water flow temp is set to 40 deg...
thanks @Mars - just watched it, and very interesting!
Our ASHP is finally installed 🙂 Because our house already had underfloor heating in every room, I was expecting the installation to be a relativel...
Tomorrow's the big day... installation! Yesterday, our energy supplier (Neon Reef) went in to administration, so we've gone from a 13p/kWh fixed pri...
HIES have responded to my email, I feel their response is actually much more informative than the response I had from MCS: First of all, I would s...
Their assumptions are listed in the heat loss calcs. I gave an example above about how their assumptions for the glass is different. It's the same fo...
I think this is exactly what's happened. All three companies have used different inputs for the wall insulation, roof insulation, glass heat loss, et...
Indeed, I thought the whole point of using MCS certified installers to provide a service was to get some level of guarantee that they do things correc...
I've updated the summary to show the calculated heat loss in watts and the heat loss W/m2 as per @Kev M's suggestion. Company A heat loss calculatio...
@editor Yes, please do. Thanks!
- 26 Forums
- 2,646 Topics
- 61.8 K Posts
- 715 Online
- 7,045 Members
Join Us!
Latest Posts
-
RE: Hitachi Heat Pump being replaced with Vaillant
Yes to be configured as a volumiser. The pump is to be...
By trebor12345 , 3 minutes ago
-
RE: Anyone concerned about GivEnergy?
So it seems subscription day has finally arrived for Gi...
By TechnoGeek , 2 hours ago
-
RE: Heat Pump Overpromising – What Were You Actually Told Before You Bought?
No, I agree entirely. There shouldn't be a need for an ...
By Majordennisbloodnok , 3 hours ago
-
RE: How many people are happy with their ASHP and do you believe them?
I agree, and not. Energy prices are a largely politica...
By JamesPa , 4 hours ago
-
RE: Solar Produced vs Home Consumed
All inverters will use solar power in preference to dra...
By JamesPa , 4 hours ago
-
Yes, you will need to notify them even if the inverter ...
By Old_Scientist , 4 hours ago
-
RE: Heat Pump Manufacturers Recommending Buffer Tanks
@tony-stolz, I think @jamespa has already covered the h...
By Mars , 17 hours ago
-
RE: Heat Pump Operation in Summer - Valliant 7kW
I do the same: cool my large buffer (3000L) to 10C, pum...
By upnorthandpersonal , 1 day ago
-
@editor "The interesting bit is that many modern invert...
By Singlespeed , 1 day ago
-
RE: Ecodan & MelCloud scheduling
With the prospect of warmer weather this week, I brough...
By downfield , 1 day ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
I reached out to MCS directly last week on this and her...
By Mars , 1 day ago
-
RE: Help me keep the faith with my air source heat pump installation
My heating developed a really severe case of noise and ...
By JamesPa , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@l2jad I was just thinking all things being equal. Our ...
By AndrewJ , 2 days ago
-
Hi, Does anybody have experience with Heat Geek insta...
By sttpd1917 , 3 days ago