Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Apr 12, 2023
@derek-m Thanks for the reply. If that was the case as you suggest how can this be improved/stopped?
@derek-m I have a question about the above discussion of the ASHP running 24/7. Through this winter ours would have had a call for heat on some day...
Thanks for the reply. I think I must be missing something. Surely if the battery kit and inverter have the Pylon protocols they must be able to talk...
Liking the 2nd battery kit. After looking around I found this 3ph hybrid inverter SUN-5/6/8/10/12K-SG04LP3 | 5-12kW | Three Phase | 2 MPPT | Hybrid ...
I flicked the DIP switch inside the unit to stop the TBH showing in the app, I told my installer and he was happy for me to do that and a few other ch...
@transparent Thanks for that post. I wasnt aware you could share one battery across 3 inverters which could be useful. I have seen 3ph hybrid inverter...
Just wondering what Hybrid inverters you guys are using with the LV battery kits? I'm struggling to find a 3 phase one that will talk to this kit. Any...
Hi, my Midea used to show the TBH until I realised it could be using it as the Midea if configured like mine isnt connected to the emersion or a boost...
I'm kind of the opposite to you guys. We are currently running 24/7 with temp comp set to 45 @ -5C & 30 @ 10C (Lounge sits at about 19.5C at this)...
To be fair I think its a steep learning curve for the installer and probably themselves and Freedom probably havent given each other the full picture ...
@cathoderay I think your right about the buffer limiting short cycling. Also our 2nd ASHP for the UFH is also plumbed into the buffer (yet to be commi...
- 27 Forums
- 2,820 Topics
- 66.9 K Posts
- 1,872 Online
- 7,234 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
Tell us about your heating system
We’ve added a few new fields to member profiles so that...
By Mars , 3 minutes ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
With a house that has a very low thermal mass that may ...
By JamesPa , 4 minutes ago
-
RE: Got two or three heat pump quotes that don’t agree? Post them here.
To the uninitiated, it's even more confusing that that....
By Rob of York , 20 minutes ago
-
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey
@toodles Thank you 🙂 I think I'm quiet lucky as the...
By HeyMikey , 1 hour ago
-
-
RE: Buffer tank on a 2 x 14kw Ecodan system
@fosterl2 I'm sure it's over simplified as there'...
By Singlespeed , 2 hours ago
-
RE: Why don't people choose heat pumps?
By the same measure we should be insisting that all gas...
By Batpred , 13 hours ago
-
RE: Load Shift and Lifestyle Shift Complete - our journey has ended, for now
I do not disagree with the concept of wanting to live a...
By Batpred , 14 hours ago
-
RE: Grant Aerona - Weather Compensation and Schedules
@taffonthetaff Yes, I have now gotten to the bottom of ...
By bontwoody , 16 hours ago
-
RE: Grant R290 DHW Cycle Interuption
Occasionally our Grant R290 activates all three circuit...
By TaffontheTaff , 17 hours ago
-
RE: Peak Energy Products V therm 16kW unit heat pump not reaching flow temperature
@davec 47kwh for 3 days is very low, compared to what I...
By johnd , 18 hours ago
-
RE: Our 10 year old Grant heat pump failed
As I understand it it was working then stopped. More l...
By JamesPa , 22 hours ago
-
@pipcart, Wattson is back... please go to the homepage ...
By Mars , 23 hours ago