Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Majordennisbloodnok
Majordennisbloodnok
@majordennisbloodnok
Moderator
Famed Member
Joined: Dec 31, 2021
Last seen: Oct 3, 2026
Topics: 35 / Replies: 2108
Reply
RE: Vaillant service impasse

I've been thinking about this and can't help but feel that in parallel to getting the issue sorted out there's a good case to be made for a bit of nam...

2 months ago
Reply
RE: PV and battery long payback - sense check query

There's an article here on using a commando socket instead of a wallbox. From a practicality viewpoint, a commando socket is either on or off; eithe...

2 months ago
Reply
RE: Vaillant service impasse

@davidb, I've just looked up the Vaillant heat pump guarantee Ts and Cs and whilst it clearly says you should get your heat pump serviced every calend...

2 months ago
Reply
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house

Almost all of them will appear like that at the moment, @ian-s, since the service is still fairly young. The confidence score will start to show more ...

2 months ago
Reply
RE: PV and battery long payback - sense check query

To be frank, my interest in burrowing into the G98/G99/G100 details is purely personal. My original reason for raising the whole issue is to clarify f...

2 months ago
Reply
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house

I suspect it's pretty well known now on this forum that I'm not a fan of Aira's general lack of openness an apparent keenness to mark their own homewo...

2 months ago
Reply
RE: PV and battery long payback - sense check query

No - that's what G100-2 gives you. An 8kW inverter that's export limited to 3.68kW is 8kW without G100. An 8kW inverter that is *output* limited to 3....

2 months ago
Reply
RE: PV and battery long payback - sense check query

Unfortunately, @davidb,this last reply of yours will have superceded that other reply you were creating so I don’t think you’ll be able to retrieve it...

2 months ago