My house was given an EPC rating of B, which I felt was generous, because the process doesn't take account of some of the thermal deficiencies such as...
My system has one of the Telford Tempest cylinders with a 50 litre buffer tank in the bottom. It seems to work very efficiently (claimed COP of about ...
Is that the flow temperature (which the heat pump decides) or the target room temperature (which is an input for deciding the flow temperature)? For e...
Is a heat pump using a few kW continuously considered to be a more onerous design condition than an electric shower which could use 9kW but for only a...
This is an awkward problem which provides a taste of the challenges arising from the objective of decarbonising home heating (IMO all new-build nomes ...
I had the 7kW Arotherm+ installed a few months ago. It was what the only local installer who made a credible quote offered and my research had reveale...
Where is you distribution board? In the I would have expected, based on my installation, that proximity of battery to your distribution board to be mo...
FWIW, here's my cylinder after the pipework was finished and before the pipe insulation was added. The 3-port valve is very accessible. It's possible ...
I think it's this cylinder(I've got one).
Something I'll flag up here is that heat pumps need diverter actuator heads and not the more common mid-position devices. I'm aware of the differenc...
The surge management problem is an interesting challenge. One million batteries all starting to charge at 5kW is a 5GW load. IIRC, the Dinorwig pumped...
Anyone can sign up to the Octopus Go tariff (I've been on it for several years and have yet to get an EV). The Intelligent Go tariffhowever, gives mor...
- 26 Forums
- 2,265 Topics
- 50.6 K Posts
- 511 Online
- 5,924 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Who has a V2G EV installation
They certainly look stylish! But it seems that Ander...
By Batpred , 6 minutes ago
-
RE: UFH downstairs and radiators upstairs balancing question
@walnut-tree-cottage - Pop all the heads off the UFH ra...
By ASHP-BOBBA , 7 minutes ago
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
And if MCS don’t have one on record that’s an issue bec...
By Mars , 38 minutes ago
-
RE: My DIY Heat Pump installation
@polar-bear, I take my hat off to you. I wish I had the...
By Mars , 42 minutes ago
-
RE: Electricity price predictions
One persons view In sync with the Nesta figures s...
By Jeff , 3 hours ago
-
RE: Oil Boiler & Heat Pump Hybrid System
So in that case they do have an incentive for you, as t...
By Transparent , 4 hours ago
-
RE: Flexi-Orb Heat Pump Scheme: A Game-Changer for the UK's Heat Pump Industry
Ok so that seems to be the key point namely only mcs ca...
By JamesPa , 5 hours ago
-
RE: One flow valve appears to be duff
You might want to consider the following common faults:...
By IaAck , 12 hours ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
We are on the Intelligent Octopus Go tariff. We instal...
By GrahamF , 14 hours ago
-
RE: New build installation query
@paullacey While the others wait for more info do you m...
By ASHP-BOBBA , 23 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
I have only just spotted this post, sorry I missed it e...
By JamesPa , 1 day ago
-
RE: British Gas Heat Pump Installation Complaint
@bgno, the other consideration for legionella cycles ar...
By Mars , 1 day ago
-
@old_scientist I dont monitor the tank temperature but ...
By bontwoody , 1 day ago
-
RE: Say hello and introduce yourself
Hello @paultheheating - I'm a rural Moderator! What's...
By Transparent , 1 day ago
-
RE: What valves to replace radbots?
Yes. Radbots just replace TRV heads. TRV heads push t...
By JamesPa , 2 days ago
-
RE: When will fusion be producing energy?
I am thinking of the case where AI was able to distingu...
By Batpred , 2 days ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
Very definitely. I think the market has changed a bit...
By JamesPa , 2 days ago
-
RE: Buying large amp bidirectional RCD and RCBO
The following diagram is taken from the Meter Operator'...
By Transparent , 3 days ago