Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 25, 2026
OK The actual text of the condition was: Within six weeks of the decision being issued, an ‘at-source’ noise survey at the Air Source Heat Pum...
If you post the link to the planning application I'm happy to take a look.
It will be in the planning application or the supporting documents, which will be (or at least should be) on the LPA's planning portal.
From what I recall The IoA spreadsheet doesn't bother with the last 4 steps in the MCS calculation. These steps are entirely pointless as the pass/fa...
I will try: predicted = (in both cases) as predicted by the documents submitted for the planning application (not sure what they said, but whate...
According to BS 8233 an attenuation of 15dB can be assumed for a wall with a window closed or ajar. So I would say very likely (according to BS 8233)...
Quite possibly true, but that's not the extrapolation the report seeks to make (as I understand it). It seeks to extrapolate from an NR achieved at o...
Of course not. I agree 100% that neither NAPIT nor MCS are the enforcement mechanism. They cannot be, because they are working for installers (a...
My solar PV experience was in 2011 and actually very good in terms of the design/installation itself. It was done end to end by one guy running his o...
@derek-m Fair cop (or COP?). That just shows how easy it is to interpret something in a way that one expects not read what it actually says. This is...
Does it conflate the two, the bit about heat pumps (reproduced below) talks about energy efficiency not cost savings so far as I read it. I guess you...
I don't wish to be the bringer of bad news and, as I have said, I understand and sympathise with your concerns but... The NR curves are very ...
- 27 Forums
- 2,800 Topics
- 66.2 K Posts
- 2,487 Online
- 7,206 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: How will removing the standing charge on gas bills benefit heat pumps?
The BUS grant funding for 2026/27 will run out at the c...
By Rob of York , 2 hours ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
Thanks @susannasaunders for reviving the topic I find i...
By springswood , 3 hours ago
-
RE: New Build 3 Phase or 1Phase
Not so any more.... 1: It's now the...
By Transparent , 16 hours ago
-
@editor Ouch, sorry to re start the tick. I had assume...
By DavidB , 2 days ago
-
RE: Say hello and introduce yourself
@e-a-west as the good Major said, welcome to the forums...
By Mars , 2 days ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
Yes I actually have a copy of a tool that whenever a ce...
By EtchedPixels , 2 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
@editor Hi, To resolve this, please tap on the A...
By Indevolt Tech , 2 days ago
-
RE: Double or Triple Glazed Windows?
Posted by: @singlespeed With 9 years repairing windo...
By Rob of York , 3 days ago
-
@transparent we’re still running a secure version of PH...
By Mars , 3 days ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
Much longer than that here. The heating isn't even on. ...
By bobflux , 4 days ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
Obviously the weather is changeable but there's a defin...
By Singlespeed , 4 days ago
-
RE: Forum updates, announcements & issues
Get the Renewable Heating Hub heads-up on WhatsApp. I...
By Mars , 4 days ago
-
RE: Safety study for plug in batteries out to tender - looks like Q3 2027 at best before legal
@editor I pointed out to the one of the Fuse execs that...
By dansus , 4 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews As well as loft insulation, there are othe...
By Rob of York , 4 days ago