Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 12, 2026
For me the sole purpose of the glycol or antifreeze valves is to provide backup protection if the power fails for any length of time; the freeze stat ...
Most heat pumps have specs on minimum clearances, perhaps check this. That said I agree with @transparent that an open frame construction would be ...
Agree. I changed mine because I reheat only once per day, which is fine so long as hysterisis set too high cause it to skip a cycle. However you see...
Thats interesting and exactly what one installer said to me. We seriously need to do a survey of door blower testers - @editor have you any contacts...
Based on my own experience there are installers out there who will use more realistic values for ACH and/or take note of measured data. They are in t...
My 200l Vaillant DHW tank falls from 70 to 65 (immediately following a legionella cycle) in about 11 hrs, just shy of 0.5C/hr. Yours is quite a lot f...
Completely agree that 'efficiency' is strictly incorrect terminology. The efficiency (of a heat pump) would be (something like) heat out/theoretical ...
I completely agree based on my personal experience, and I have now heard a sprinkling of installers say this, but is there any wider evidence that you...
... If as a result you can turn the flow temp down then that could make quite a difference!
So your heating COP is (30-4)/(10.5-2.5) = 3.25 Your DHW COP is 4/2.5 = 1.6 As you imply sacrificing COP for low cost electricity saves money. Its...
No process is 100% efficient, so yes some is lost from pumps, electronics, pipework etc. I think Vaillant monitor deltaT and flow rate to calculate e...
Overall about 43/15 = 2.85 However this is made up of space heating COP and DHW COP, which normally are quoted separately, because they are typicall...
- 27 Forums
- 2,817 Topics
- 66.7 K Posts
- 2,125 Online
- 7,230 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
Should I change my cylinder when changing from a gas boiler to a heat pump.
I have 178 L Gledhill unvented cylinder which was fitte...
By David , 1 hour ago
-
Should I change my cylinder when changing from a gas boiler to a heat pump.
I have 178 L Gledhill unvented cylinder which was fitte...
By David , 1 hour ago
-
RE: Plug and play solar. Thoughts?
Impressions so far from the one I've installed are that...
By EtchedPixels , 3 hours ago
-
-
@batpred The Daikin temperature probe protrudes from th...
By Toodles , 6 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
@editor And as an occasional contributor, may I say wel...
By Toodles , 8 hours ago
-
RE: Should Households Who Can Afford It Pay More for Energy to Help Those Who Can't?
They don't have to try. Our entire system is d...
By EtchedPixels , 9 hours ago
-
RE: Why don't people choose heat pumps?
Fair enough. I guess I was thinking of pipes that run ...
By JamesPa , 9 hours ago
-
RE: How Can I Prove Coal Was My Main Heating Source Without Receipts?
Got excepted for the grant now so thanks for the replie...
By Chilli304 , 13 hours ago
-
Daikin Altherma 3 R F+W, room thermostat control, weath...
By JanHarley , 13 hours ago
-
RE: Buffer tank on a 2 x 14kw Ecodan system
Pretty much as I had guessed in my crude scaling from m...
By JamesPa , 16 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
Well you have a vibration generator running at some fre...
By bobflux , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
@downfield Thats a decent rate, I’m shocked they hadn...
By Papahuhu , 2 days ago
-
RE: Adventures in heat loss calculations
@toodles thanks! So as suspected, around a doubling of ...
By SusannaSaunders , 2 days ago