Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 23, 2026
Topics: 28 / Replies: 5526
Reply
RE: In the Bleak Midwinter... Midea heat pump performance, poor COP and windchill in action

This is definitely an interesting scenario. What I think happens is this. The house fabric starts (when it's cold) with a thermal gradient continual...

2 years ago
Reply
RE: In the Bleak Midwinter... Midea heat pump performance, poor COP and windchill in action

Phew! I thought I was going mad. In terms of #2 rapidly warming OAT is an interesting phenomenon in terms of understanding the thermal dynamics of a...

2 years ago
Reply
RE: In the Bleak Midwinter... Midea heat pump performance, poor COP and windchill in action

I'm now a bit confused. I thought we had more or less proved that the problem lies with the water pump and thus there is insufficient flow of heat fr...

2 years ago
Reply
RE: Baffled by heat pump size/ choice!

More expensive, larger, louder and won't modulate down so low and are thus less efficient for space heating if the house doesn't need it. If you real...

2 years ago
Reply
RE: Baffled by heat pump size/ choice!

Yes, sorry for any confusion. 10C is sometimes quoted as the temp of incoming mains (being, I presume, roughly the temp underground at the level the ...

2 years ago
Reply
RE: Baffled by heat pump size/ choice!

another is to fit waste water heat recovery

2 years ago
Reply
RE: Baffled by heat pump size/ choice!

OK lets go with 6, 8 minute showers at 10l/min. So you need 480l of water at 40C. If you start of with 300l at 48C (a common setting) and mix it wit...

2 years ago
Reply
RE: Baffled by heat pump size/ choice!

Any heating set up with either variable or low flow temperature does this. In the UK we normally set up boilers to run at a high fixed flow temperatu...

2 years ago
Reply
RE: Baffled by heat pump size/ choice!

We need to do some energy calculations! Over what period do you need 8 showers and do you know the water flow rate even roughly. We need these numbe...

2 years ago
Reply
RE: 6 Red Flags to Avoid When Considering a Heat Pump Installation

The ASHP, just like a boiler, can supply water at only one temperature at any time. So it switches between space heating and DHW. There will be one ...

2 years ago
Reply
RE: 6 Red Flags to Avoid When Considering a Heat Pump Installation

@mars That could be a whole discussion in itself. I don't personally think its simple!

2 years ago
Reply
RE: New Samsung 12KW Heat Pump Help

Unless you have a time of use tarriff/economy 7 then the most economical way to heat DHW is when its warmest outside, generally mid afternoon. Howeve...