Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 14, 2025
@transparent sounds like the problem is already solved then, they just need to get everyone using the same solution? then anyone with internet can hav...
@kenm with a buffer tank (or LLH) you always have the possibility of imbalance in flow rates between each side. which will mean any or all of mixing o...
@cathoderay thanks, I had a read. The network diagram is quite good - better than I was expecting. Very clear in explaining what the proposal is. as...
@transparent interesting. do you have a link? I couldn't find it. Architecting this kind of technology is exactly what I do professionally, but never...
@prjohn I totally sympathise as you are being economically disadvantaged by not having access to the cheaper tariffs available with a working smart me...
@gary as I read it, you can't be on Intelligent (import @7.5p) and Outgoing (export @15p) at the same time. It has to be Outgoing Lite which is 8p, on...
@kenm so I have an evohome controller also, was used to run my house with gas boiler. it is still there but I have slowly reduced its role in the syst...
Intelligent Octopus. I have a large battery (40kwh) and 2 EV's so I optimise cost by pulling a large amount of night offpeak at best possible price . ...
@jwilliams89 if you can do a really good job on the insulation then 10kwh may take you a long way: In my case: a 210m2 house which has loads in the ...
I trust your tongue is firmly in your cheek here? speaking as someone who lives an an area with where the mobile operator that was previously "the b...
@editor do you know your heat loss for your home? its size in m2? the heat outputs that your system is generating for these inputs? presumably because...
@jwilliams89 vertical column types as a general rule need to be larger (WxH) than K2's for the same output. as no convector fins. but its more about w...