Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

HarriUp
@harriup
Member
Estimable Member
Joined: Nov 25, 2021
Last seen: Jun 28, 2025
Topics: 1 / Replies: 107
Reply
RE: Mitsubishi Ecodan Fails to Heat Water despite temperature drop

@m1kegibson If you are able to access the service menu settings and navigate to the thermistor readings, I suspect you may find the answer as to wh...

10 months ago
Reply
RE: Ecodan consuming 100kwh per day in new build!!!

@anca1808 I'd certainly backup the suggestion from @rhh2348 to check the consumption as measured by the unit - I know it is the main culprit in your h...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

Thanks @abernyte - I remember seeing this video before, the technicalities are still beyond me but the general idea is useful to understand. Like...

1 year ago
Reply
RE: Ecodan 6kW - is it "cycling", or normal operation?

@clockworks Looking at your flow temperature graphs, the rise before the pump stops is not particularly big. You could try this: Under Operation set...

1 year ago
Reply
RE: Ecodan with FTC7 controller DHW schedule

The default setting is that the DHW is always 'on' but actually runs when the tank temperature drops below the max temp drop value. To force the DHW t...

1 year ago
Reply
RE: Ecodan 6kW - is it "cycling", or normal operation?

"cycling is bad" - cycling can either indicate the inevitable result of the heat demand falling below the heat output of the pump or it can be a failu...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

For clarity: The only reference to system volume I can find in the documentation I have relating to my EcoDan refers to the space heating circuit. The...

1 year ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

@alsocold123456 Only the primary circuit runs during the defrost cycle so shouldn't be taking heat out of the water sitting in the secondary heating ...

1 year ago
Reply
RE: Best temperature wave form for best economy and efficiency .

Amps - yes, you did say. Not the most useful measure to have graphed though!To your examples:Lets say 34 is the temperature at which the radiators to ...

1 year ago
Reply
RE: Best temperature wave form for best economy and efficiency .

I think this might be a different set of parameters for the user to interact with than the typical uk/european ones. That lower green line I commented...

1 year ago
Reply
RE: Can you work an ASHP too hard?

As someone with an over-sized HP and the lower level of performance this entails for much of the year this strategy has a lot of appeal! I have a good...

1 year ago
Reply
RE: Best temperature wave form for best economy and efficiency .

I find the graphs somewhat hard to reconcile against the references to 31 or 32 @ 3° ambient as in both the flow temperature seems to be targeted at t...

1 year ago