Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 19, 2023
So much of that resonates with me (and I think I have you to thank for re-visiting AA mode again). I've attached a couple of charts from the past 24...
I'm assuming the continued IAT rise is the lag effect of the three incremental/cumulative rises in target temp (I guess LWT was at it's highest / rads...
I have a theory. When thermo diff adjust mode is ON it opens up a bunch of parameters to help us control/limit it's behaviour. When it's OFF, it's unr...
My thoughts are on the same lines. Also, once OAT decreases, it will result on longer 'on' times and shorter 'off' times. I'm inclined to leave things...
+3 would be my choice. How long have you been in AA mode (I'm wondering if it has started a little high in term of target temp and needs a few more da...
Here's the scores on the doors for day three in AA mode (quite interesting - sad but true). Target temp appears to have been dropped by a further 0....
Thanks. Quite accurate - in fact I ran at a fixed flow of 38C last spring as a happy medium of still being able to heat the house at minus temps, bu...
From my experience the upper limit was ignored when thermo diff was OFF (I'd set it to 42C - it blasted through to 48C in one test). It will be intere...
@derek-m I guess not (or with not enough attention to detail) lol. I've also sussed out since that they also left the pump on a setting that gave a fl...
I've left my system in AA mode for now. Here's a representative hour from last night. Interestingly the target temp appears to have dropped by one deg...
@sunandair I'm not sure I fully understand all the maths, but that's very useful, thanks. As a side note; I notice you have three towel rails. The r...
We did discuss this on another post recently where I provided this info (you kindly provided a copy of your radiator output calculator spreadsheet). I...
- 27 Forums
- 2,792 Topics
- 66 K Posts
- 3,311 Online
- 7,196 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
I think Heat Geek have done an amazing job on their bra...
By Tomtheheatingengineer , 2 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
I have just had 3 heat loss surveys, one by heat geek o...
By David , 3 hours ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
I think that's the key question. After all inverter uni...
By Prunus , 4 hours ago
-
RE: battery storage without solar
As of October 1st they need specific qualifications to ...
By EtchedPixels , 5 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
A unit which uses water to transfer the heat/chill from...
By Temperature_Gradient , 5 hours ago
-
RE: Renewables & Heat Pumps in the News
With regards to the BUS grant raid, I gave it more thou...
By ASHP-BOBBA , 6 hours ago
-
RE: Why are ASHP installs so expensive?
The whole system seems to work on the basis of...
By ian33a , 6 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
Good plan. If you can get half hourly meter readings a...
By JamesPa , 11 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
@editor Most certainly. The heat pump was an ideal s...
By Abernyte , 11 hours ago
-
Although regulations may well vary from country to coun...
By Majordennisbloodnok , 12 hours ago
-
RE: Does anyone have experience of a smart water meter?
Yep I caught our slow leak from a £100 bill rise 8)
By EtchedPixels , 12 hours ago
-
RE: Do You Need a Buffer Tank or Low Loss Header for Underfloor Heating in a Large Property?
@jamespa in some cases, failing the Turing test might b...
By GrahamF , 15 hours ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
@energystoragetech The heat capacity of some...
By JamesPa , 17 hours ago
-
RE: tepeo ZEB UK Support & Info Thread
Sorry you are correct, I was remembering figures from t...
By JamesPa , 1 day ago
Members Online
No online members at the moment