So much of that resonates with me (and I think I have you to thank for re-visiting AA mode again). I've attached a couple of charts from the past 24...
I'm assuming the continued IAT rise is the lag effect of the three incremental/cumulative rises in target temp (I guess LWT was at it's highest / rads...
I have a theory. When thermo diff adjust mode is ON it opens up a bunch of parameters to help us control/limit it's behaviour. When it's OFF, it's unr...
My thoughts are on the same lines. Also, once OAT decreases, it will result on longer 'on' times and shorter 'off' times. I'm inclined to leave things...
+3 would be my choice. How long have you been in AA mode (I'm wondering if it has started a little high in term of target temp and needs a few more da...
Here's the scores on the doors for day three in AA mode (quite interesting - sad but true). Target temp appears to have been dropped by a further 0....
Thanks. Quite accurate - in fact I ran at a fixed flow of 38C last spring as a happy medium of still being able to heat the house at minus temps, bu...
From my experience the upper limit was ignored when thermo diff was OFF (I'd set it to 42C - it blasted through to 48C in one test). It will be intere...
@derek-m I guess not (or with not enough attention to detail) lol. I've also sussed out since that they also left the pump on a setting that gave a fl...
I've left my system in AA mode for now. Here's a representative hour from last night. Interestingly the target temp appears to have dropped by one deg...
@sunandair I'm not sure I fully understand all the maths, but that's very useful, thanks. As a side note; I notice you have three towel rails. The r...
We did discuss this on another post recently where I provided this info (you kindly provided a copy of your radiator output calculator spreadsheet). I...
- 22 Forums
- 2,067 Topics
- 45.3 K Posts
- 18 Online
- 3,338 Members
Join Us!
Trusted Installers
Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.
✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available
Latest Posts
-
RE: Load Compensation and Weather Compensation
In the context of a single zone heat pump system a valv...
By JamesPa , 5 hours ago
-
Move to a different contractor, 16mm pipe every day not...
By Johnmo , 11 hours ago
-
RE: How accurate was your heat loss survey?
For me: Two full surveys (each taking 3hrs, one of whic...
By JamesPa , 11 hours ago
-
RE: Nibe F2040 periodic warm water increase fails
Ok. The key point I think you have made is that the er...
By JamesPa , 11 hours ago
-
RE: Air Changes per Hour - ACH and the MCS requirement
@matwin If you plan to commission one it might b...
By JamesPa , 12 hours ago
-
RE: Jokes and fun posts about heat pumps and renewables
In a similar vein, this recent spell of sustained good ...
By Majordennisbloodnok , 17 hours ago
-
RE: Home energy storage & battery register
By the end of next month... 8 kW PV + Tesla Powerwall...
By Algienon , 18 hours ago
-
RE: Enabling WiFi: Samsung ASHP on Smart Things App
@grahamh-uk Yes, I have the same Samsung controller p...
By Old_Scientist , 19 hours ago
-
RE: Various different approaches to battery storage.
I thought I'd share my story/journey and experiences he...
By Old_Scientist , 20 hours ago
-
RE: Commencing on an ASHP Installation Process
It varies by room, but the conservatory is assumed at 2...
By Sheriff Fatman , 24 hours ago
-
RE: Antifreeze top up for my heat pump - is this a rip off?
@editor @sallyl As Mars said, there are 2 different typ...
By Brendon Uys , 2 days ago
-
RE: Renewables & Heat Pumps in the News
Here on the Forum we're going to need to be increasingl...
By Transparent , 2 days ago
-
What I Wish I Knew Before Installing a Heat Pump
I’m putting together the next Homeowners Q&A episod...
By Mars , 2 days ago
-
RE: Planning Update: 1 Metre Boundary Rule for Heat Pumps Has Been Scrapped
In Scotland they still follow the MCS rules, so the noi...
By Johnmo , 2 days ago
-
RE: Getting the best out of a heat pump - is Homely a possible answer?
@johnmo and @benson Thanks! I was aware there was a p...
By MarcT , 2 days ago
-
RE: Is your heat pump insured?
My insurer just asks the question: "Is your home heated...
By AndrewJ , 3 days ago
-
RE: Vaillant & OVO partner up to offer Heat Pump Plus
Slippery slope starting
By Johnmo , 3 days ago
-
RE: Say hello and introduce yourself
@cathoderay Ah yes, that’s the name! The Heat Pimp, It’...
By Toodles , 3 days ago
-
By the way, I also think our industry need to get on bo...
By ASHP-BOBBA , 5 days ago