Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 13, 2025
@carpenterstation Yep that looks all normal, if you want to turn the heating off and leave the hot water on then you have to do it from the controller...
@robs Is this only in the newer controllers I don't have that option on my FTC5
[quote data-userid="6617" data-postid="44648" The DHW COP is the worst we've had yet strangely. And there were no big drains on the water yesterday. ...
Yes it’s really there to allow the heat pump to vary the flow temp above the set point if the room temp is significantly below the set point and then ...
On an Ecodan the std compensation curve mode only allows the flow temp to drift by 1 or 2C before it shuts off on auto adapt the allowable drift is pr...
32C is the lowest my system will go without cycling but at that flow temp the heat input is higher than the heat loss so the thermostat has to cut in ...
@robs What controller do you have I think mine is too old to have that, I don't recall ever seeing summer mode in the service menu.
Mitsubishi Ecodan just runs the same flow temp when it reaches the limit of the set curve. I am not aware of any way of telling the heat pump not t...
I suppose it depends on what battery you get I can only comment on the powerwall I had my first for 5 years before the inverter went and it was at 95%...
Yep exactly that
With a flow of 40C the dT for a 20C room temp is 20 it’s the difference in temp between flow and room. The output of a rad at dT 20 is 0.3 of its out...
- 27 Forums
- 2,783 Topics
- 65.6 K Posts
- 1,287 Online
- 7,187 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Indevolt Batteries UK Support & Info Thread
So what's the bet that the established installation ind...
By JamesPa , 16 minutes ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Looks like an impressive bit of kit. Just ...
By Batpred , 18 minutes ago
-
RE: Getting closer to a finished Haier system
Fantastic. I am wondering how the support from Haier...
By Batpred , 22 minutes ago
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
The idealist in me says pioneers in this space should b...
By Batpred , 27 minutes ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
@ashp-bobba, I thought it was an interesting parallel. ...
By Mars , 3 hours ago
-
RE: Adding additional Solar Panels to a DC coupled battery system
@transparent No it was my baby, entirely delivered by m...
By bontwoody , 5 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Ah, that makes sense when a combi is in place. The boil...
By Batpred , 1 day ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
@bobflux Thanks, that gives me something to check the i...
By Paul1098 , 1 day ago
-
RE: Tesla Powerwall (2) Calibration Cycles
For Powerwall calibration, avoid forcing repeated deep ...
By EnergyStorageTech , 1 day ago
-
Over the years, due to the non barrier PEX underfloor h...
By bobflux , 2 days ago
-
RE: battery storage without solar
Indeed, current on the grid input = current used for ch...
By bobflux , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu @papahuhu A lot of tears and sweat went into ...
By Andris , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
We have the same problem, 12 mature trees clip the morn...
By Papahuhu , 4 days ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
I had a battery and inverter installed a while ago, my ...
By Batpred , 4 days ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@ltron2 The EPC on our house is A-92, however that i...
By Rob of York , 4 days ago