Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 13, 2025
@carpenterstation Yep that looks all normal, if you want to turn the heating off and leave the hot water on then you have to do it from the controller...
@robs Is this only in the newer controllers I don't have that option on my FTC5
[quote data-userid="6617" data-postid="44648" The DHW COP is the worst we've had yet strangely. And there were no big drains on the water yesterday. ...
Yes it’s really there to allow the heat pump to vary the flow temp above the set point if the room temp is significantly below the set point and then ...
On an Ecodan the std compensation curve mode only allows the flow temp to drift by 1 or 2C before it shuts off on auto adapt the allowable drift is pr...
32C is the lowest my system will go without cycling but at that flow temp the heat input is higher than the heat loss so the thermostat has to cut in ...
@robs What controller do you have I think mine is too old to have that, I don't recall ever seeing summer mode in the service menu.
Mitsubishi Ecodan just runs the same flow temp when it reaches the limit of the set curve. I am not aware of any way of telling the heat pump not t...
I suppose it depends on what battery you get I can only comment on the powerwall I had my first for 5 years before the inverter went and it was at 95%...
Yep exactly that
With a flow of 40C the dT for a 20C room temp is 20 it’s the difference in temp between flow and room. The output of a rad at dT 20 is 0.3 of its out...
- 27 Forums
- 2,778 Topics
- 65.5 K Posts
- 1,856 Online
- 7,185 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Estimating true heat loss from twelve months of consumption data
Finally, after what seems like an eternity, we paid a d...
By ian33a , 3 hours ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
@paul1098 — as we are getting down to the nitty gritty,...
By cathodeRay , 15 hours ago
-
RE: Tesla Powerwall (2) Calibration Cycles
I’ve had two calibration cycles in the last three month...
By Davesoa , 20 hours ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@editor That's a pity, but thank you for checking. I'l...
By ltron2 , 1 day ago
-
My fifth heat pump book, Heat Pumps Explained, is out n...
By Mars , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
Just furkled Into the parameter menu. Found the master ...
By AgentGeorge , 2 days ago
-
RE: Analysis of the economics of switching to an A2W ASHP compared to other heat sources
It's interesting that Norway with a much colder climate...
By Rob of York , 2 days ago
-
RE: Review your electricity provider
Happy to add Scottish Power and the review 'dont touch ...
By JamesPa , 2 days ago
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
Yes, and I would suggest likely to get worse with more ...
By Batpred , 4 days ago
-
RE: Electricity price predictions
This topic seems more suitable for this thread... I a...
By Batpred , 4 days ago
-
RE: Why are ASHP installs so expensive?
It is clearly difficult to say, there must be cases whe...
By Batpred , 4 days ago
-
RE: Panasonic Free Multi Z and Etherea Internal units.
@dgclimatecontrol Thank you for that information and re...
By Toodles , 4 days ago
-
RE: My Kronoterm Adapt 0312 ASHP is finally installed!
@editor It was serendipitous really. Both my wife and I...
By tomasmcguinness , 4 days ago
-
@mrkfm, I'd also suggest that whenever you're ready, st...
By Mars , 4 days ago